Aquanova Scorpio 1700 Fixed Seat & Transfer System Information Pack www.abacushealthcare.com Abacus Healthcare Services Ltd, Unit 1 Millennium W ay, High Carr Business Park, Newcastle-under-Lyme, ST5 7XE 0808 256 4249 Tel: 01782 569330 Fax: 01782 569349 Sales: 0800 454810 www.abacushealthcare.co.uk...
Page 2
Contents Technical Speci cation Pre-Installation Instructions Installation Instructions Care and Maintenance Customer Instruction Certi cates...
Page 3
Scorpio 1700 Technical Speci cation Maximum User Weight : 150Kg Maximum Water Capacity : 200 litres Approximate Bath Weight (Empty) :155Kg Power Supply : Mains 230V to be supplied via 30mA RCD Operating Voltage : 24V Battery Backup : Yes Water Supply : Hot &...
Page 4
Pre - Installation Requirements Access When deciding on the positioning of the bath there are a number of points that should be taken into consideration: 1. Hoist/wheelchair access 2. Service/cleaning access 3. Positions of any existing under oor pipe work or cabling 4.
Page 6
Pre - Installation Requirements ELECTRICS The bath should be connected via a 5 Amp IP65 rated switched fused spur unit, with 2m of 1.5mm 3 core round ex trailing. Located at the tap end of the bath, positioning and speci cation to be in accordance with IEE regulations. The Spur box should be mounted between 300-500mm o the oor.
Page 7
Pre - Installation Requirements Water Pressure Requirement As the bath requires a Thermostatic Mixing Valve which has been manufactured to NHS engineering specification D08 and approved under the TMV scheme, please read the following which outlines how a TMV may affect the use of your bath. The working parameters of the TMV require a water pressure of 1-5 bar with a maximum pressure loss ratio of no greater than 10:1 between hot and cold feeds.
Page 8
Pre - Installation Requirements Minimum Dimensions for Access: Doorway: - 825mm. Corridor : - 825mm Consideration must be allowed to manoeuvre the bath around the hallways etc. Dimensions A 1269mm B 1700mm This document details the requirements C 750mm D 365mm which must be in place to ensure E 1335mm F 960mm...
Page 9
Scorpio 1700 Installation Instructions Items Items supplied with the kit should be as follows: Information pack (This pack) User manual Bath unit complete (Bath Shell, Outer panels, Frame, Control pack) Bath surround panels - inner Flexible water feed pipes x2 User handset Lap Belt Bath shower mixer tap (TMV) - optional...
Page 10
Scorpio 1700 Installation Instructions Tap & Waste Connection Connect the taps using the flexible water pipes provided making sure they do not snag when the bath is lifted. Trimming of the inner lower & outer upper panels may be required to fit the panels around the pipe.
Page 11
Scorpio 1700 Installation Instructions WARNING In the event of mains failure during use of bath, back-up batteries will enable the bather to exit the bath. Immediately after installation, it is vital that the bath be connected to a mains supply for at least 24 hours before initial use, to ensure the batteries are fully charged .
Scorpio 1700 Installation Instructions TROUBLE SHOOTING Some basic checks are detailed below if in doubt contact service support on 0870 066 0809. Bath Does not move Check Power: Check Spur Fused to ensure there is power to the unit. Ensure the RCCB is working and has power to it. To test the RCCB push the test button;...
Scorpio 1700 Customer Instruction Certi cate Testing the Bath WARNING! The system batteries must be charged for 24 hours prior to using the bath. You may test the bath to ensure it is working correctly. Ensure that hands and objects are kept away from the underside and topside when operating the bath.
Page 14
Any consequence arising from unskilled or incorrect handling of the product is not covered by this guarantee. The following items, when supplied by Abacus Healthcare are guaranteed for a period of twelve months from the date of supply for the parts only (labour costs are not covered).
Page 15
Scorpio 1700 Customer Instruction Certi cate Customer Instruction Certificate Customer Name_______________________________________________ Bath No:_____________________________________________________ Instruction given on the following: Operating your Scorpio Bath Safety Warning Caring for your Scorpio Bath Transfer System (if fitted) Person Receiving Instruction:___________________________________ Signed:______________________________ Date:________________________________ Instructed By:_________________________ Signed:______________________________ Date:________________________________ Customer Copy...
Page 16
Scorpio 1700 Customer Instruction Certi cate Customer Instruction Certificate Customer Name_______________________________________________ Bath No:_____________________________________________________ Instruction given on the following: Operating your Scorpio Bath Safety Warning Caring for your Scorpio Bath Transfer System (if fitted) Person Receiving Instruction:___________________________________ Signed:______________________________ Date:________________________________ Instructed By:_________________________ Signed:______________________________ Date:________________________________ File Copy...
Need help?
Do you have a question about the Aquanova Scorpio 1700 and is the answer not in the manual?
Questions and answers