Download Print this page

Bauer HYPERMAX 191101C-B Owner's Manual & Safety Instructions page 13

Cordless auto-feed drain cleaner
Hide thumbs Also See for HYPERMAX 191101C-B:

Advertisement

troubleshooting
problem
Motor shuts off
1. The motor may have been shut off
during use.
2. GFCI breaker tripped.
Cable kinks, twists,
1. Too much force on the cable.
or breaks.
2. Too much space between
3. Cable used is wrong size
4. Cable exposed to acid.
5. Cable worn out.
Cable tangles
1. Too much force on the cable.
in drum.
2. Motor running in reverse.
3. Autofeed mechanism frozen.
Follow all safety precautions whenever diagnosing or servicing the tool.
Disconnect Battery pack and charger power supply before service.
pLEaSE rEaD tHE FOLLOWinG carEFuLLy
THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM
IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR
MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS
QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE
ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY
STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND
LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY
ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS
THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.
Item 64483
possible causes
by its internal thermal protection
switch, or auto reset breaker.
Drain Cleaner and drainpipe inlet.
for drain pipe.
For technical questions, please call 1-888-866-5797.
Likely Solutions
1. Turn Rotation Switch to OFF. Allow motor to
cool off completely before restarting and stay
clear of cable when turning motor back on.
2. Make sure all electrical components are dry and
all insulation is in good repair. Press reset button.
If GFCI trips again, have appliance serviced
by qualified electrician before further use.
1. Do not force cable. Let Drain Cleaner do the work.
2. Move Drain Cleaner to within
6 inches of drainpipe inlet.
3. Change cable size.
4. Clean and oil cable after each use.
5. Replace cable.
1. Do not force cable. Let Drain Cleaner do the work.
2. Retract Cable with the rotation
Switch in the forward position.
3. Technician should lubricate autofeed
mechanism bearings.
Page 13

Hide quick links:

Advertisement

loading

This manual is also suitable for: