  • Page 1 Instruction Manual YPM-06C Please read the instructions completely before using this product This product is designed for household use only.
  • Page 2 INTRODUCTION Thank you for choosing Our Portable Air Conditioner. We hope you enjoy this stylish and practical unit, which is designed for improving your living and working comfort. Please read this manual carefully before using this product. The following tips may help to maximize the efficiency of your air conditioner: •...
  • Page 3: Important Safeguards

    IMPORTANT SAFEGUARDS When using electrical appliances, basic safety precautions should always be followed: 1. Read all instructions 2. To protect against fire, electric shock and personal injury, do not immerse cord, plugs, or the unit in water or other liquid. 3.
  • Page 4: Lcdi Power Cord And Plug

    LCDI POWER CORD AND PLUG This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug. The LCDI power cord and plug will shut off the supply source via electrical disconnect (circuit trip) if the nominal current leakage between the cord shield and either load conductor exceeds a predetermined value.
  • Page 5: Parts Names

    PARTS NAMES Features: 1. 3 in 1 portable air conditioner, cooling, fan and dehumidifying function. 2. Colorful LED display with remote control. 3. Quiet and easy operation. 4. Auto defrosting function. 5. 24 hour timer on/off function. 6. Auto swing function of horizontal.
  • Page 6: Installation

    INSTALLATION 1. Select a proper installation location Place the portable air conditioner on a flat and dry location where the air outlets cannot be obstructed. Leave a 20” (50 cm) minimum space between the product and the wall. 2. Assemble the air exhaust hose Connect the end of the hose and adapter- twist them.
  • Page 7 4. Install the window kits Your window kit has been designed to fit most standard "vertical" and "horizontal" window applications. However, it may be necessary for you to improvise/modify some aspects of the installation procedures for certain types of windows. Notes: The length of hot air exhaust hose is between 11〞to 59〞...
  • Page 8 OPERATING INSTRUCTION 1.Control panel Cautions: If the unit is turned off in cool mode and restarted immediately, it will wait in 3 minutes at least before running. Press this button to turn on/off the unit. POWER Press this button to select cool , fans or dehumidify function. MODE Press this button to make the horizontal louver swing.
  • Page 9 2. LED Indicator Temperature and time indicator Cooling mode indicator Fan mode indicator Dehumidifying indicator Sleep mode indicator Auto mode indicator Timer mode indicator Low fan speed indicator High fan speed indicator Swing function indicator 3. Remote control Press this button to turn on / off the unit. POWER Press this button to select Auto, Cooling, Fan or MODE...
  • Page 10 OPERATING INSTRUCTION 1. Simple steps to use cooling mode Plug in the power cord and press the “POWER” button Press “MODE” to chose COOLING mode. Press “UP” or “DOWN“ to set the desired temperature. The temperature ranges from 59F to 86F(15C~30C) Press, “SPEED”...
  • Page 11: Auto Defrost

    Dehumidifying: 5℃ < room temperature < 21℃ 7. Auto defrost When the air conditioner is used in the cooling or dehumidifying mode in low room temperature conditions it will develop internal frost. When the frost gets to heavy and the efficiency is being compromised the unit will go into a defrost mode automatically and E4 will be displayed.
  • Page 12: Water Drainage

    WATER DRAINAGE The water tank in the unit will fill when the air conditioner is used in the dehumidifying mode or run in an area with high humidity. When water tank is full, water full indicator will light and display will show P2 as alarm, the air conditioner will be shut off automatically.
  • Page 13: Surface Cleaning

    Remove the water stopper to empty the water in the air conditioner. Clean air filter. Have the air conditioner run in fan mode at low fan speed for 4hours, to ensure the internal air conditioner is dry, to avoid any mildew growth in it.
  • Page 14: Troubleshooting

    TROUBLE SHOOTING Please check the air conditioner by yourself referring to the following chart before contacting professional service. Trouble Is no power supply? Is water full? The unit doesn’t work Is the room temperature too high? Is Timer function activated?