Summary of Contents for Brada Appliances MPN1-08CR
Page 1
MPN1-10CR Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner.
The power cord is equipped with a three-prong grounding plug for protection against shock hazards. Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle.
IDENTIFICATION OF PARTS Accessories Check all the accessories are included in the package and please refer to the installation instructions for their usage. Suggested tools for window kit installation 1. Screwdriver(medium size Phillips) 2. Tape measure or ruler 3. Knife or scissors 4.
Before Using This Air Conditioner, be Sure To Check The Back Of The Unit To Make Sure That The Lower Drain Plug Is Security In Place . See Fig.2 FRONT VIEW Fig.1 REAR VIEW Fig.2 NAMES OF PARTS IDENTIFICATION OF PARTS...
Before you begin, thoroughly familiarize yourself with the control panel and remote controller and all functions, then follow the symbol for the functions you desire. The unit can be controlled by the unit control panel alone or with the remote controller . OPERATION PANEL OF THE AIR CONDITIONER SWING AUTO...
If error repeats, call for service. Bottom tray is full - Connect the drain hose and drain the collected water away. If error repeats, call for service. AIR CONDITIONER FEATURES light illuminates " " To Operate on Fan Only" "...
TIMER ON To operate on Auto feature: TIMER OFF In this mode, the fan speed can not be adjusted, When you set the air conditioner in AUTO mode, it will automatically operation to control room temperature set by you. To operate on Cool feature: Press the ADJUST buttons select your desired room temperature.
TIMER button SWING AUTO COOL MODE AIR CONDITIONER FEATURES NOTE: When the unit is on, first press the Timer button, the indicator light above word TIMER OFF illu- minates. It indicates the Auto Stop program is initiated. When the unit is off, first press the Timer button, the indicator light above word TIMER ON illu- minates.
OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS COOL OPERATION Press the "MODE" button several times until the "COOL" indicator light comes on. Press the UP and DOWN buttons The temperature can be set within a range of 17 C-30 C/62 F-88 F. Press the "FAN " button to choose the fan speed. DRY OPERATION (DEHUMIDIFY) Press the "MODE"...
P1 symbol disappears. If the error repeats, call for service. Remove the drain plug Fig.4 OPERATING CONDITION The air conditioner must be operated within the ambient temperature range indicated below: MODE COOL attach a section of drain hose (included with "...
Maximum:123cm(4.04ft). Fig.9 INSTALLATION INSTRUCTIONS Location The air conditioner should be placed on a firm foundation to minimize noise and vibration. For safe and secure positioning, place the unit on a smooth, level floor strong enough to support the unit. The unit has casters to aid placement, but it should only be rolled on smooth, flat surfaces.
Page 13
Foam seal A (adhesive type) Fig.10 Window kit 27 ~ 48 67.5 cm ~ 123 cm Window stool Fig.11 Window kit Window stool Fig.12 Foam seal Fig.13 INSTALLATION INSTRUCTIONS Installation in double-hung sash windows 1. Cut the foam seal(adhesive type) to the proper length and attach it to the window stool.
INSTALLATION INSTRUCTIONS Foam seal A (adhesive type) Fig.14 Window kit 27 ~ 48 Fig.15 Fig.16 Foam seal Fig.17 Installation in a sliding sash windows 1. Cut the foam seal(adhesive type) to the proper length and attach it to the window frame. See Fig.14. 2.
Flat mouth Fig.18 Hook Fig.19 Fig.20 Fig.21 INSTALLATION INSTRUCTIONS Exhaust hose installation: The exhaust hose and adaptor must be installed or removed in accordance with the usage mode. COOL mode FAN or DEHUMIDIFY mode 1. Install the window Exhaust adaptor (flat mouth) onto the exhaust hose as shown in Fig.18.
CARE AND MAINTENANCE Air filter (slide out) Fig.22 Remove the screw and take the air inlet grille down Fig.23 Remove the air filter out from the grille Fig.24 Power cord Band Fig.25 Fig.26 CARE AND MAINTENANCE IMPORTANT: 1) Be sure to unplug the unit before cleaning or servicing. 2) Do not use gasoline, thinner or other chemicals to clean the unit.
TROUBLE SHOOTING TROUBLES 1. Unit does not Start when Pressing on/off Button 2. Not cool enough 3. Noisy or vibration 4. Gurgling sound POSSIBLE CAUSES - P1 appears in the display window - Room temperature is lower than the set temperature.(Cooling mode) - The windows or doors in the room are not closed.
Handling the remote controller CAUTIONS The air conditioner will not operate if curtains, doors or other materials block the signals from the remote controller to the indoor unit. Prevent any liquid from falling into the remote controller. Do not expose the remote controller to direct sunlight or heat.
Remote Controller Specifications Model R51I13/BG(C)E Rated Voltage 3.0V(Dry batteries R03/LR03 2) Lowest Voltage of 2.0V CPU Emitting Signal 8m (when using 3.0 voltage, it Gets 11m) Signal Receiving Range Environment -5 C 60 C( NOTE: Temperature setting display: Fahrenheit scale( F), R51I13/BG(C)E Performance Feature 1.
REMOTE CONTROLLER ILLUSTRATION Function buttons continued SET TEMPERATURE( F) AUTO COOL HIGH TEMP ON/OFF MODE FAN SPEED SWING TIMER ON ECONOMY TIMER OFF RESET LOCK DISPLAY Model: R51I13/BG(C)E Indicators on LCD SET TEMPERATURE TIMER ON OFF TIMER ON Button Press this button to activate the Auto-on time setting. Each press will increase the time setting in 30 minutes increments, up to 10 hours, then at 1 hour increments up to 24 hours.
Page 21
FAN SPEED SWING ECONOMY TIMER ON 1. In the AUTO mode, the air conditioner can logically choose the mode of Cooling, Fan, TIMER OFF RESET LOCK DISPLAY 2. In the AUTO mode, you can not switch the fan speed. It has already been automatically 3.
Page 22
Press it again to stop. When the louver swing or move to a position which would affect the cooling effect of the air conditioner, it would automatically change the swing/moving direction. ECONOMY(SLEEP) operation The ECONOMY/SLEEP function is only available under Cooling, and AUTO operation.
The TIMER OFF feature is useful when you want the unit to turn off automatically TIMER OFF after you go to bed. The air conditioner will stop automatically at the set time. Example: To stop the air conditioner in 10 hours.
Need help?
Do you have a question about the MPN1-08CR and is the answer not in the manual?
Questions and answers