Advertisement

Quick Links

Manual
DoorCom IP Multi
DCIP 740-01

Advertisement

Table of Contents
loading

Summary of Contents for SSS Siedle DoorCom IP Multi DCIP 740 Series

  • Page 1 Manual DoorCom IP Multi DCIP 740-01...
  • Page 2: Table Of Contents

    Contents 1 System description 2 Safety remarks System requirements 3 Structure DCIP 740‑... Siedle Multi Terms 4 Components Calling Input module, camera module Power supply, programming, IP video server Software Siedle Multi 5 Installation Terminals DCIP 740‑... LED displays Block diagrams Wiring diagram Siedle Multi 6 Commissioning DCIP 740‑...
  • Page 3: System Description

    1 System description 2 Safety remarks System requirements DoorCom IP Electrical voltage Find out about the necessary safety Siedle DoorCom IP links the Siedle measures and system requirements world of building communication to before starting installation and com‑ the IP world. missioning of the DoorCom IP.
  • Page 4: Structure Dcip 740

    3 Structure DCIP 740‑... Siedle Multi Camera assignment mode PRI 602-... USB DCIP 740‑... Camera assignment mode A separate supply is consequently Siedle Multi link The SIM 740‑... is assigned to a not required. An optionally con‑ door/ camera. In this mode, the nected DCA 740‑01 is supplied from The DCIP 740‑...
  • Page 5 Monitor assignment mode PRI 602-... USB • Reception of status messages from maximum conductor length of the • Selective connection to a door sta‑ the Siedle Multi bus device connection must not exceed tion (Audio and/or video) • Speech connection via PC 1 metre.
  • Page 6: Terms

    3 Terms Client IP address Multicasting PC user connected to a network. Internet Protocol address Term to denote group/parallel calls An IP address is a number which with video image to several PC users Gateway permits PCs and other devices in an which have the Software Client Gateways link two different sys‑...
  • Page 7 Subnet mask The subnet mask, also known as The universal serial bus (USB) is a network mask, is a bit mask which serial bus system for connection separates an IP address into a net‑ of a computer to external devices. work and a device or host section.
  • Page 8: Components

    4 Components for DCIP 740‑... Call buttons BTM 650-01 to 04 Bus call button modules for In‑Home bus 1‑4 call buttons, integrated LED lighting. Connection by means of ribbon cable to the bus door loud‑ speaker. Supply to the LED lighting via terminal b and c with 12 V AC, current consumption 20 mA per bus call button module BTM 650‑...
  • Page 9: Input Module, Camera Module

    4 Components for DCIP 740‑... Input module, camera module CMC 612‑... Camera module, colour. Integrated 2‑step heating system, day/night switchover, infrared lighting and video signal transformer. Power supply using line rectifier NG 600‑... or VNG 602‑... With Siedle Multi via PCM 640‑.../NG 600‑..., NG 608‑... or NG 640‑... Heating power supply 12 V AC, 100 mA.
  • Page 10: Power Supply, Programming

    4 Components for DCIP 740‑... Power supply, programming, video server NG 600‑0 Line rectifier in 10‑grid switch panel housing for universal power supply. Suitable for surface mounting with ZAP 10‑0. Primary 230 V AC, 50 Hz, +6%‑10% Secondary b/c: 14 V AC, 1 A; +/‑: 24‑28 V DC, 0.7 A Ambient temperature 0°C to +40°C, protection rating IP 20...
  • Page 11: Software

    4 Device overview for DCIP 740‑... Software CDs contain • DoorCom IP Software Client • DoorCom IP Configuration soft‑ ware • DoorCom IP Manual • Siedle default configuration for IPVS 600‑... • Java Runtime Environment (JRE) 5.0 • Microsoft Installer 3.1 DCIP CO 600‑0 DoorCom IP configuration software PC program for set‑up and program‑...
  • Page 12: Siedle Multi

    4 Device overview for DCIP 740‑... Siedle Multi SIVS 610‑0 System interface video server, for connection of Siedle Multi to the IPVS 600‑... . The SIM 740‑0 is required for connection. The SIVS 610‑... features galvanic isola‑ tion. Dimensions 144 x 130 x 55 mm SIM 740‑0 The Multi system interface processes all Multi data protocols.
  • Page 13: Installation

    5 Terminals DCIP 740‑... Terminals and LEDs IPVS 600‑01 a 12 V DC power input for connecting the power supply b Connecting socket to the SIVS 610‑... c LED LINK lights up in green with an existing network connection d RJ45 socket ETH network connection e LED ACT lights up in orange on data transmission via the network...
  • Page 14: Led Displays

    5 LED displays LED signalling SIVS 610‑... Switching on LED green LED red Function After reset, power on: Device boots to operating status. The boot area is checked. Software runs in the flash Fast flashing After a software update, the boot area is recreated. This can take up to around 3 minutes.
  • Page 15 LED signalling IPVS 600‑... The IP video server IPVS 600‑... has 3 LEDs which can display operating statuses and can provide an indication of possible errors: LED power on the top and the LED LINK and LED ACT on the underneath. LED Power Function IPVS 600‑...
  • Page 16: Block Diagrams

    5 Terminals SIVS 610‑0, SIM 740‑0 Block diagram SIVS 610‑0 Reference for the inputs E1–E4 Input 4, call button 4 (7.4) Input 3, call button 3 (7.3) Input 2, call button 2 (7.2) Input 1, call button 1 (7.1) Power supply for Vario bus, 12 V DC, max.
  • Page 17 5 Terminals CMC 612‑... Block diagram CMC 612‑... +M/-M Supply voltage Video 20 ‑ 30 V DC Vc/‑ Actuation from door loudspeaker for camera on. With DoorCom IP the contact is permanently active. Potential ‑ is switched via the UPS terminal. Actuation of camera distributor ‑M is switched A1/A1 Potential‑free contact for additional applications...
  • Page 18: Wiring Diagram Siedle Multi

    5 Installation DCIP 740‑... Siedle Multi...
  • Page 20 5 Installation DCIP 740‑... Siedle Multi DCIP 740‑... Siedle Multi Remarks a) Door release 12 V AC, use at least Function 20 Ohm (e.g. TÖ 615‑...) Depending on the operating mode b) 12 V AC consumers in the wiring camera assignment or monitor diagram: assignment, 4 or 49 PC users can •...
  • Page 21: Commissioning

    6 Commissioning DCIP 740‑... Siedle Multi Commissioning of the DCIP 740‑... is Connection of the PC to IPVS 600‑... broken down into four steps: 1 Configuration of IPVS 600‑... 2 Configuration of SIM 740‑... 3 Configuration of SIVS 600‑... 4 Installation of the software DCIP SC 600‑...
  • Page 22 6 Configuration of SIM 740‑... Configuration of SIM 740‑... SIM addresses Messages Programming the SIM 740‑... takes In the mask SIM addresses, the phys‑ In the Messages mask, status mes‑ place using a connected PC via ical Multi bus addresses are selected sages are configured which are dis‑...
  • Page 23: Multicasting

    6 Configuration Multicasting Multicasting Multicast address video 1 Multicast package TTL Alongside the 1:1 connection Enter a valid multicast address for A value can be entered which deter‑ between one encoder and one each stream of the relevant encoder mines how long the multicast data receiver (Unicast) the IPVS 600‑...
  • Page 24: Configuration Software Dcip Co 600

    6 Configuration software DCIP CO 600‑... Step 3: Connection of the PC to IPVS 600‑... Configuration of SIVS 610‑... The configuration software DCIP CO 600‑... is required for configuration of the SIVS 610‑.../ SIM 740‑... . Configuration takes place via a Windows PC. Serial con‑ nection to the SIVS 610‑...
  • Page 25 • Selection of the required speech connection, half duplex or full duplex • Input of the IP address of the IPVS 600‑.. for which the con‑ figuration is applicable. This input is required to ensure that the Software Clients are able to locate the DCIP in the network.
  • Page 26: Client-Software Dcip Sc 600

    6 Client‑Software DCIP SC 600‑... Step 4: Installation of the Software Clients The Software Client DCIP SC 600‑... must be installed on every PC you wish to receive door calls. The Software Client communicates with the calling station, the DCIP 600‑... . After installation, the file (*.dcip) generated using the configuration software must be imported.
  • Page 27 Possible error sources Other settings in the Software • No speech connection from the Client: PC to the door. The microphone amplifier may not be activated. Free buttons • Installation must take place as Selection of functions for buttons administrator, so that all registered 1‑3.
  • Page 28: Setting The Speech Volume

    7 Setting the speech volume Level adjustment DCIP 740‑... Level adjustment IPVS 600‑... Level adjustment TLM 645‑... Level adjustment DCIP 740‑... Setting the volume of the PC user in Setting the volume of the PC user Set the volume of the speech con‑ the direction of the door station.
  • Page 29: Doorcom Dca 740-01

    8 DoorCom DCA 740-01 9 DoorCom IP Factory setting IPVS 600‑... The DoorCom Analog DCA 740‑... With the reset button at the is used as an interface between IPVS 600‑..., it can be reset to the DoorCom IP and an analog tel‑ as‑delivered status. It is essential to ephone connection of a telecommu‑...
  • Page 30: Glossary, Index

    10 Glossary Index The current issue of the “DoorCom Connection AEM 645‑... IP” system manual is available from As‑delivered status BTM 650‑... the download area under Block diagram CMC 612‑... 9, 17 www.siedle.de. Camera assignment 4, 6 COM 611‑... Technical additions or printing Client 6, 26 DCA 740‑...
  • Page 32 S. Siedle & Söhne © 2012/07.01 Telefon- und Telegrafenwerke OHG Printed in Germany Best. Nr. 0-1101/037983 EN Postfach 1155 78113 Furtwangen Bregstraße 1 78120 Furtwangen Telefon +49 7723 63-0 Telefax +49 7723 63-300 www.siedle.de info@siedle.de...

This manual is also suitable for:

Doorcom ip multi dcip 740-01