Gas Leak Test

Check places for the outdoor unit.
Setting of Remote Control
Selector Switch
When two indoor units are installed in the separated rooms, it is not
necessary to change the selector switches.
Remote control selector switch
• When two indoor units are installed in the same room or adjacent two
rooms, if operating a unit, two units may receive the remote control
signal simultaneously and operate. In this case, the operation can
be preserved by setting either one indoor unit or remote control to B
setting (Both are set to A setting in factory shipment).
• The remote control signal is not received when the settings of indoor
unit and remote control are different.
• There is no relation between A setting/B setting and A room/B room
when connecting the piping and cables.

Remote Control A-B Selection

To separate using of remote control for each indoor unit in case of 2 air
conditioners are installed near.
Remote Control B Setup.
1. Push and hold [
] button on the Remote Control by the tip of the
pencil. "00" will be shown on the display. (Picture 1)
2. Press
during pushing [
will disappear and the air conditioner will turn OFF. The Remote Control
B is memorized. (Picture 2)
Note : 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A has not "A" display.
3. Default setting of Remote Control from factory is A.
1
Check places for fl are nut connection
(Indoor unit)
Valve cover
• Check the fl are nut
connections for the gas
leak with a gas leak
detector or soap water.
]. "B" will show on the display and "00"
2

OTHERS

OTHERS
Unit B setup.
Press and hold
When A setup changed to B setup : 5 beeps will sound and operation
lamp blinks for 5 seconds.
When B setup changed to A setup : 5 beeps will sound.
To switch the TEST RUN (COOL) mode, press [OPERATION] button for
10 seconds (The beeper will make a short beep).

Auto Restart Function Setting

This product is designed so that, after a power failure, it can restart
automatically in the same operating mode as before the power failure.
Information
The product was shipped with Auto Restart function in the OFF position.
Turn it ON as required.
How to turn ON the Auto Restart Function
• Press and hold the [OPERATION] button on the indoor unit for 3 seconds
(3 beep sounds and OPERATION lamp blink 5 time/sec for 5 seconds).
How to turn OFF the Auto Restart Function
• Press and hold the [OPERATION] button on the indoor unit for 3 seconds
(3 beep sounds but OPERATION lamp does not blink).
NOTE
• In case of ON timer or OFF timer are set, AUTO RESTART OPERATION
does not activate.
13
button for more than 20 seconds.

Test Operation

A
EN
ES
FR
IT
DE
PT
PL
CZ
RU
CR
HU
TR
NL
GR
SV
FI
NO
DK
RO
BG
EE
LV
SK
SI

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-b13j2fvg-eRas-b18j2fvg-e

Table of Contents