Install The Valve - Kohler K-402 Installation Manual

Thermostatic mixing valve
Hide thumbs Also See for K-402:

Advertisement

Available languages

Available languages

Cold Water
Supply Line
Hot Water
Supply Line
K-401
Cold Water
Supply Line
Hot Water
Supply Line
K-400

3. Install the Valve

CAUTION: Risk of product damage. This valve contains plastic
and rubber components. Do not sweat or braze directly to the
valve body. Do not apply excessive heat to the valve body when
you make solder connections. Do not apply flux or acids directly
to the valve or you may damage the seals and plastic
components.
CAUTION: Risk of product damage. Do not apply
petroleum-based lubricants to the valve components or damage
may result.
NOTE: A plaster guard is attached to the face of the mixing valve
with two screws. Do not remove it until instructed.
Flush the hot and cold water supply lines to remove any debris.
Install water hammer arrestors in the hot and cold water supply