6.1































EN-18
System-specific parameters
Sets the preparation of swimming pool water
Sets the external temperature below which
domestic hot water preparation is carried out
with 2 compressors in 2-compressor heat
pumps
In parallel operation, the maximum number of
compressors available in the network is
displayed here. The number of these that are to
be used for swimming pool water preparation
can be selected.
Sets the desired swimming pool temperature
Sets the desired swimming pool temperature
with parallel cooling operation
The hysteresis of the swimming pool set
temperature forms the neutral zone below
which a swimming pool request will be issued.
Sets whether the waste heat recovery during
cooling is dependent on the switching status of
the thermostat or in continuous operation
Sets the time programs for blocking swimming
pool water preparation
Sets the times at which a swimming pool block
is to take place
For each day of the week, it is possible to select
whether Time1, Time2, no time or both times
are to be active for a swimming pool block.
Blocks that exceed a weekday are activated or
deactivated at the end of each day accordingly.
Sets the time programs for a priority of
swimming pool water preparation
Sets the start time for the swimming pool
priority
Sets the desired number of hours for which
swimming pool priority should be given
For each day of the week, it is possible to select
whether a priority is desired at the set start
time.
The output of the auxiliary circulating pump can
be configured to allow parallel operation of the
auxiliary circulating pump and the heat pump's
compressor. Configuration is possible for
heating, domestic hot water preparation and
swimming pool water preparation. Frost
protection functions are ensured.
Should the auxiliary pump operate during
heating operation?
Setting range
Display
Swimming pool
-30 °C
Swimming pool
... 25 °C ...
2 compressors
-35 °C
(10 °C HT)
... 0 ...
Swimming pool
Paralell connection
28
Master controller
5 °C
Swimming pool
... 25 °C ...
Reversible HP
60 °C
Sensor
5 °C
Swimming pool
... 25 °C ...
Reversible HP
60 °C
Additional heat
exchanger
Sensor
0K
Swimming pool
... 0,5+K ...
Reversible HP
20K
Sensor
No
Swimming pool
Yes
Reversible HP
Additional heat
exchanger
Swimming pool
00:00
Swimming pool
...
23:59
N
Swimming pool
T1
T2
Y
Swimming pool
00:00
Swimming pool
...
23:59
1
Swimming pool
...
10
N
Swimming pool
Y
Always
No
Heating circuit 1
Yes