Heat pump manager
Hide thumbs Also See for WPM EconPlus:

Advertisement

Available languages

Available languages

6.1






























EN-16
System-specific parameters
For each day of the week, it is possible to select
whether Time1, Time2, no time or both times
are to be active when the temperature is raised.
Operations to raise the temperature that
exceed a week day are activated or deactivated
at the end of each day accordingly.
Sets the room set temperature for silent
cooling.
The actual value is measured by room climate
control station 1/2
Raises the minimum permissible flow
temperature calculated from the measured
values from room climate control station 1/2. A
raised value reduces the risk of condensate
forming.
Settings for cooling operation
Sets the time programs for dynamic cooling
Sets the times during which dynamic cooling is
blocked.
For each day of the week, it is possible to select
whether Time1, Time2, no time or both times
are to be active for a block. Blocks that exceed
a weekday are activated or deactivated at the
end of each day accordingly.
Setting to specify whether a second chiller is to
be used in the system.
Sets the external temperature below which
cooling with reversible brine HP or passive
cooling is interrupted.
If the current return set temperature for passive
cooling minus hysteresis is greater than the
current brine temperature, passive cooling
occurs.
Setting for DHW preparation
For heat pumps with 2 compressors, this sets
the external temperature below which DHW
preparation is carried out with 2 compressors.
In parallel operation, the maximum number of
compressors available in the network is
displayed here. The number of these that are to
be used for domestic hot water preparation can
be selected.
The hysteresis of the domestic hot water set
temperature forms the neutral zone below
which a request for domestic hot water will be
issued.
Does hydraulic isolation of the cooling circuit
and the domestic hot water circuit allow for
parallel operation of cooling and domestic hot
water?
Sets the desired domestic hot water
temperature
Setting range
Display
N
Heating circuit 2
and 3
T1
Heating
T2
Y
15.0 °C
Cooling function
... 20.0 °C ...
Heating circuit 2
30.0 °C
and 3
1,5K
Cooling function
...3,5K...
Heating circuit 2
5K
and 3
Cooling function
Cooling function
Dyn. cooling
00:00
Cooling function
...
Dyn. cooling
23:59
N
Cooling function
T1
Dyn. cooling
T2
Y
No
Cooling function
Yes
-20 °C
Cooling function
... 3 °C ...
Brine heat pump
35 °C
0.1K
Cooling function
... 2.0K ...
passiv
9.9K
Brine heat pump
Domestic hot water
-30 °C
Hot water
... -25 °C ...
2 compressors
35 °C
(10 °C HT)
0
Hot water
... 1 ...
Paralell connection
28
Master controller
2K
Hot water
...
Sensor
15K
No
Hot water
Yes
Sensor
Passive cooling
function
30 °C
Hot water
... 60 °C ...
Sensor
85 °C