Specifications - RFS APD-D Series Product Manual

Automatic pressurization dehydrator
Table of Contents

Advertisement

9 SPECIFICATIONS

 
GENERAL 
Output Flow, Minimum, Nlm (SCFM) 
3
Max System Volume, liters (ft
), @ 34.5 kPa (5 psig) 
Output Dew Point, Minimum, Celsius (Fahrenheit) 
Operational Pressure, psig (kPa) 
Pressure Deadband, psig (kPa) 
Ambient Operational Temperature Range 
Ambient Operational Humidity Range 
Operational Noise, dBA @ 1 meter, Standby 
Operational Noise, dBA @ 1 meter, Active 
Output Pressure Safety Relief 
Output Fitting Type 
Maximum Continuous Operation, Active 
ELECTRICAL 
Operating Voltage, AC 
Source Frequency, Hz, Nominal (Range) 
 
Max. Standby Current, Amps
Max. Active Current, Amps 
Max. Active Power Consumption, Watts 
Max. Active Power Consumption, Volt‐Amps 
Power Factor Correction, typical 
Electrical Feed Circuit Configuration 
Electrical Feed Circuit Size Recommendation 
Electrical Inlet Connector 
ALARMS 
Alarm Configuration 
Alarm Contact Rating, Maximum
Low Pressure Alarm (Standard on all units) 
SIZE AND WEIGHT 
Dimensions, H x W x D, inches (mm) 
Net Weight, pounds (kilograms) 
ENVIRONMENTAL 
Max. Operational Altitude @ 5 psig, feet (meters) 
Max. Operational Altitude @ 10 psig, feet (meters) 
Derating per 1000ft (305m) above MSL, CFM (lm) 
Options: (Field Configurable) 
Low Pressure Operation 
High Pressure Alarm 
Humidity Alarm 
Run Time Alarm 
System Purge 
Compliance 
CE (EMC, MD, PED, RoHS) 
IEC 60529‐IP20 
NOTES: 
1)
All specifications at 23°C (73 F) and 50% Relative Humidity at mean sea level (MSL) unless otherwise noted. 
2)
For indoor use only. IEC 60721‐3‐3 Class 3k3 (temperature‐controlled enclosed locations, humidity not controlled), 
Humidity: 25 g/m3 Absolute Humidity @ 85% RH = 29.4°C, 40°C @ 25 g/m3 Absolute Humidity = 48.8% RH. 
3)
Tubing used must be polyurethane (durometer 95A), polyethylene (durometer 44D), or nylon (durometer 50D). 
4)
Voltage source per IEC 60038 (1/N/PE) ***Not for use with North American 240VAC service*** 
5)
Electrical supply circuit must remain within operating voltage specifications at all times. 
6)
Lower Operational Pressure fixed at 0.5 psig (3.4 kPa), Low Pressure alarm fixed at 0.25 psig (1.7 kPa). 
Page 20 of 24
APD20‐D 
5.65 (0.2) 
3500 (123)
120V +/‐10% 
60Hz (47‐63Hz) 
 
Standard configurations: Fixed at 0.5 psi (3.4 kPa) below lower operational pressure 
6,500 (1,930) 
5,000 (1,525) 
0.024 (0.68) 
Software configurable from 1‐2.5 psig (6.9‐13.8 kPa) in 0.5 psig (3.4 kPa) increments 
Software configurable from 3‐11 psig (20.7‐75.9 kPa) in 1 psig (6.9 kPa) increments 
APD22‐D 
4.8 (0.17) 
1
 
3000 (106)
Ambient dew points <= 10° (50°): ‐40° (‐40°) dew point 
Ambient dew points > 10° (50°): 50° (72°) dew point reduction 
Firmware configurable from 1‐10 (6.9‐68.9) 
Firmware configurable from 2‐9 (13.8‐62.1) 
0‐40°C (32‐104°F) 
5‐85% relative, non‐condensing (maximum absolute humidity = 25 g/m
60 
Fixed at 15 psig (103.4 kPa) 
Quick‐Connect, 3/8" OD Plastic Tube 
230V +/‐10% 
50Hz (47‐63Hz) 
320 
280 
380 
290 
Single Phase, 3‐Conductor (Phase/Neutral/Ground) 
IEC 320 Type C14 
1 Form C relay contacts, screw terminal connector 
Low Pressure configurations: Fixed at 0.25 psig (1.7 kPa) 
9.5 x 13.5 x 9.5 (242 x 343 x 242) 
25 (11.4) 
6,000 (1,830) 
4,500 (1,370) 
0.022 (0.62) 
Software configurable from 20‐50% RH in 10% RH increments 
Software configurable from 10 minutes to 4 hours in 10 minute increments 
Software configurable from 2‐10 days in 2 day increments 
Model 
APD70‐D 
19.8 (0.7) 
1
1
 
16500 (582)
 
2
 
3
 
4 Hours 
4
 
120V +/‐10% 
60Hz (47‐63Hz) 
0.5 
500 
520 
0.8 
5
15 Amps 
 
30VDC, 1A 
30 (13.6) 
12,400 (3,780) 
10,900 (3,325) 
0.07 (1.98) 
602400011500
Revision C
APD72‐D 
16.4 (0.58) 
1
13500 (477)
 
3
2
 
66 
4
230V +/‐10% 
 
50Hz (47‐63Hz) 
420 
440 
4
 
11,500 (3,500) 
9,500 (2,900) 
0.06 (1.70) 
6
 

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the APD-D Series and is the answer not in the manual?

This manual is also suitable for:

Apd20-dApd70-dApd22-dApd72-d

Table of Contents