9 SPECIFICATIONS
GENERAL
Output Flow, Minimum, Nlm (SCFM)
3
Max System Volume, liters (ft
), @ 34.5 kPa (5 psig)
Output Dew Point, Minimum, Celsius (Fahrenheit)
Operational Pressure, psig (kPa)
Pressure Deadband, psig (kPa)
Ambient Operational Temperature Range
Ambient Operational Humidity Range
Operational Noise, dBA @ 1 meter, Standby
Operational Noise, dBA @ 1 meter, Active
Output Pressure Safety Relief
Output Fitting Type
Maximum Continuous Operation, Active
ELECTRICAL
Operating Voltage, AC
Source Frequency, Hz, Nominal (Range)
Max. Standby Current, Amps
Max. Active Current, Amps
Max. Active Power Consumption, Watts
Max. Active Power Consumption, Volt‐Amps
Power Factor Correction, typical
Electrical Feed Circuit Configuration
Electrical Feed Circuit Size Recommendation
Electrical Inlet Connector
ALARMS
Alarm Configuration
Alarm Contact Rating, Maximum
Low Pressure Alarm (Standard on all units)
SIZE AND WEIGHT
Dimensions, H x W x D, inches (mm)
Net Weight, pounds (kilograms)
ENVIRONMENTAL
Max. Operational Altitude @ 5 psig, feet (meters)
Max. Operational Altitude @ 10 psig, feet (meters)
Derating per 1000ft (305m) above MSL, CFM (lm)
Options: (Field Configurable)
Low Pressure Operation
High Pressure Alarm
Humidity Alarm
Run Time Alarm
System Purge
Compliance
CE (EMC, MD, PED, RoHS)
IEC 60529‐IP20
NOTES:
1)
All specifications at 23°C (73 F) and 50% Relative Humidity at mean sea level (MSL) unless otherwise noted.
2)
For indoor use only. IEC 60721‐3‐3 Class 3k3 (temperature‐controlled enclosed locations, humidity not controlled),
Humidity: 25 g/m3 Absolute Humidity @ 85% RH = 29.4°C, 40°C @ 25 g/m3 Absolute Humidity = 48.8% RH.
3)
Tubing used must be polyurethane (durometer 95A), polyethylene (durometer 44D), or nylon (durometer 50D).
4)
Voltage source per IEC 60038 (1/N/PE) ***Not for use with North American 240VAC service***
5)
Electrical supply circuit must remain within operating voltage specifications at all times.
6)
Lower Operational Pressure fixed at 0.5 psig (3.4 kPa), Low Pressure alarm fixed at 0.25 psig (1.7 kPa).
Page 20 of 24
APD20‐D
5.65 (0.2)
3500 (123)
120V +/‐10%
60Hz (47‐63Hz)
Standard configurations: Fixed at 0.5 psi (3.4 kPa) below lower operational pressure
6,500 (1,930)
5,000 (1,525)
0.024 (0.68)
Software configurable from 1‐2.5 psig (6.9‐13.8 kPa) in 0.5 psig (3.4 kPa) increments
Software configurable from 3‐11 psig (20.7‐75.9 kPa) in 1 psig (6.9 kPa) increments
APD22‐D
4.8 (0.17)
1
3000 (106)
Ambient dew points <= 10° (50°): ‐40° (‐40°) dew point
Ambient dew points > 10° (50°): 50° (72°) dew point reduction
Firmware configurable from 1‐10 (6.9‐68.9)
Firmware configurable from 2‐9 (13.8‐62.1)
0‐40°C (32‐104°F)
5‐85% relative, non‐condensing (maximum absolute humidity = 25 g/m
60
Fixed at 15 psig (103.4 kPa)
Quick‐Connect, 3/8" OD Plastic Tube
230V +/‐10%
50Hz (47‐63Hz)
3
2
320
280
380
290
Single Phase, 3‐Conductor (Phase/Neutral/Ground)
IEC 320 Type C14
1 Form C relay contacts, screw terminal connector
Low Pressure configurations: Fixed at 0.25 psig (1.7 kPa)
9.5 x 13.5 x 9.5 (242 x 343 x 242)
25 (11.4)
6,000 (1,830)
4,500 (1,370)
0.022 (0.62)
Software configurable from 20‐50% RH in 10% RH increments
Software configurable from 10 minutes to 4 hours in 10 minute increments
Software configurable from 2‐10 days in 2 day increments
Model
APD70‐D
19.8 (0.7)
1
1
16500 (582)
2
0
3
4 Hours
4
120V +/‐10%
60Hz (47‐63Hz)
0.5
5
500
520
0.8
5
15 Amps
30VDC, 1A
30 (13.6)
12,400 (3,780)
10,900 (3,325)
0.07 (1.98)
602400011500
Revision C
APD72‐D
16.4 (0.58)
1
13500 (477)
3
2
)
66
4
230V +/‐10%
50Hz (47‐63Hz)
4
420
440
4
11,500 (3,500)
9,500 (2,900)
0.06 (1.70)
6