3-3. Number of divisions and output phase difference

The MJ620 output A/B phase signals, an alarm signal, and reference point signals as shown
in Fig. 3-1.
Minimum phase difference: Tw: 100 ns (When set to a minimum phase difference of 100 ns)
Tw TwTw Tw
A
B
Resolution settings
1/4 Z
Z
AL
. The encoder travel is detected in 100-ns increments and is output at a phase difference
proportionate to the amount traveled.
The phase difference changes in integral multiples of 100 ns.
. The A/B phase signals are at high impedance during output of the alarm signal.
6
(E)
Tw +Nx100 ns
N: Fluctuation due to travel speed
Fig. 3-1
Travel
High impedance
direction
reversal
400 ms