Lockout (Power-up) and Automatic
The use of the luminaire at switchable power outlets can be optimised using the lockout (power-up). When
Lockout is activated (Power-up Off), the luminaire remains in standby mode after any power failure until
presence is detected or it is switched on manually. When Lockout is deactivated (Powerup On), the luminaire
switches on automatically after any power failure. The EPURIA Lighting Management enables the completely
automatic operation of luminaries at the workplace without any intervention of the user being necessary. When
semi-automatic (PIR off only) is activated, the luminaire is in fact switched off during absence, however
switching on the luminaire must be performed manually. As a result, maximum energy saving is possible.
Unintended, automatic switching on (e.g. in areas near corridors) is prevented.
Set-up of luminaires with daylight and presence detection
To ensure optimal functioning of the system, ensure that
the sensors are allocated to the work area when setting
up the luminaire.
*Table size: 200 x 100cm
Status LED
Status LED...
...flashes green (every 3 sec)
...flashes 1x red
...flashes 2x red
...flashes 3x red
EPURIA-S can be controlled also by using an IR6 remote control:
Symbol
Name
ON
ON
OFF
OFF
Dim up
Dim down
Automatic mode
AUTO
Set current light level
SET
00157562/P-/AS/02.2020
Luminaire is in the „Bright Out Mode"
Motion detected
Infrared command received
DSI Programmer communication running
Description
Switch-on of the luminaire
Switch-off of the luminaire
Increase current dim level
Reduce current dim level
Luminaire switches on (if previously in standby)
→ light regulation is started (if not permanently deactivated)
Store the brightness level currently measured by the sensor as target value for
constant light control (press button >3s)
2 EN