1.1Restoration of initial value............................... 3
1.2 Software version display................................. 3
1.3 Product serial number display........................ 3
2.1Interface type selection..................................... 4
2.1.1Protocol type mode........................................ 5
2.1.2 RS-232 Interface setting..............................10
2.2 Scan mode setting...........................................14
2.3 Sound setting...................................................17
2.4 String character setting....................................18
2.5 Other settings..................................................20
Chapter 3 .Bar code setting
3.1
UPC-A........................................................ 22
3.2
UPC-E.........................................................24
3.3
EAN-13....................................................... 26
3.4
EAN-8......................................................... 28
3.5
Code 39....................................................... 30
3.6
Codabar....................................................... 33
3.7
Code 93....................................................... 35
3.8
Code 128/EAN-128.................................... 37
3.9
Interleaved 2 of 5..................................... 39
3.10 Industrial 2 of 5........................................ 41
3.11 Matrix 2 of 5................................................43
3.12 China post code........................................... 45
3.13 MSI/Plessey................................................ 47
3.14 Code 32....................................................... 49
3.15 Code 11....................................................... 51
3.16 RSS(optional)
Appendix A............................................................ 53
Appendix B............................................................ 55
- 1 -

Advertisement

Table of Contents
loading

Summary of Contents for Lindy 20789

  • Page 1: Table Of Contents

    ¢ ¡ ¤ £ ¦ ¥ ¤ ¡ ¦ § ¨ © ¡ ¦      ¦  ¤  ¢    ¦ ¡ ¦  ¤  ¦    £ ¤   ! ¡ ¤ § §¡ ¦ "   ¤ £ #$ ¢...
  • Page 2 Flow chart of bar code reader setting G 3 H I " P R Q S T V U TW ! X P PX P W ` Y TQ Q X P W b a cQ S T V U I " d H ae " T f C ! A 3 5 4 @ 3 A 3 B 1 C ! 7 3 6 3 2 8 9 g 3 5 3 C ! h E 7 3 5 8 9 7 3 B i B 2 3 p 3 g 3 E B 2 3 6 ‘...
  • Page 3: Chapter 1System Information

    Chapter 1System information 1.1 Restoration of initial value System setting will be reset and restored to factory initial state through bar code scanning. 1.2 Software version display Display software version number through bar code scanning. 1.3 Product serial number display Display product serial number through bar code scanning.
  • Page 4: Chapter 2 System Setting

    Chapter 2 System setting 2.1 Interface type selection This type of bar code reader can support 3 kinds of interface ˜User can reset according to their needs ˜It is to be noted that the bar code reader can only read data into the mainframe if the on-line access to the interface is consistent with the settings.
  • Page 5 2.1.1 Keyboard interface parameters Keyboard protocol type Select the type of host to connect the keyboard ˜Select bar code interface according to the host interface cable ˜ Set begin Option Item IBM AT(default) IBM XT IBM PS/2 30-80 IBM 5550 Protocol type keyboard PS/2 25 ¨30 NEC 9801...
  • Page 6 Keyboard language selection: It doesn’t only support American-style keyboard ¨ but also a variety of languages. Set begin Option Item America ˜default ¯ Italy Italy France Language option Germany Japan Reserved Reserved Set end - 6 -...
  • Page 7 Function key emulation (IBMAT) When the bar code contains 01 to 1F of the ASCII code value ¨if it is set ON ¨ bar code reader outputs corresponding code ¨it is equal to pressing a function key ˜Direct scanning of bar codes in Appendix B can also implement function key simulation.
  • Page 8 Caps Lock key This function key is related to the Caps lock key of the keyboard function ¨ upon switched on ¨it is equal to pressing the Caps Lock key ˜ Num Lock key This function can only be effective to PC/ AT ¨upon switched on, it is equal to pressing the Num lock key of the keyboard ˜...
  • Page 9 Keyboard data end mark (for the keyboard interface) Keyboard interface of the bottom of the output data ˜ Delay after each data transfer section(for the keyboard interface) Delay timer, which is an output of each bar code data ˜ This feature is generally used to send frequent short bar code data or to transmit multi- bar codes at once, delay time = data set*100(ms) Keyboard speed select the host which matches its speed ˜...
  • Page 10 2.1.2 RS-232 Interface setting RS-232 Basic setting of communication protocols ¨ including baud rate, data bit, stop bit, calibration, etc ˜ Set begin Option Item 1200bps 2400bps 4800bps Data bit 9600bps(default) 19200bps 38400bps 7digits Transmission baud rate 8digits(default) Set end - 10 -...
  • Page 11 Set begin Option Item 1digit(default) Stop bits 2digits None(default) Odd parity Check setting Dual check Mark check Space check Set end RS-232 function setting At RS-232 interface mode ¨ the client can proceed the following aspects according to own requirements (including the suffix data ˆ...
  • Page 12 Delay after each data transmission(for RS-232):Each bar code data output a delay timer ˜This feature is generally used to send frequent short bar code data or transmission of multiple bar codes simultaneously, the delay time set data = * 100 (ms) Protocol response delay Wait for host handshake signal time, delay time = set data * 100 (ms) Set begin...
  • Page 13 Set begin Option Item None CR+LF ˜default ¯ Data suffix STX/ETX Set end - 13 -...
  • Page 14: Scan Mode Setting

    Set begin Option Item None(default) RTS/CTS Flow control ACK/NAK Xon/Xoff Set end 2.2 Scan mode setting Button switch mode: Hold down the trigger to begin scanning ¨scanning would be completed upon the trigger released or when the scan decoding is successful ˜When it is successful ¨release the trigger ¨then hold it down again ¨will begin the next decoder ˜...
  • Page 15 could be re-read after the light disappeared. Hold down the trigger to stop the continuous scanning ˜ Test mode: Hold down the trigger to start testing ¨ continuous scanning the barcode ¨ hold down the trigger again to stop the testing ˜ Each time the trigger has been held down, it only read once it only could be changed to another way through scan mode to exit.
  • Page 16 Set begin Option Item Button switch mode turn OFF mode after identification(default) Continuous recognition/ Guan mode key Test reading mode Scan mode Continuous recognition/LED ON Continuous recognition/Timeout off Scintillation Continuous recognition/No Trigger - 16 -...
  • Page 17: Sound Setting

    Set end 2.3 Sound setting You can adjust the level of buzz and beep tone regulation time. It is allowed to set the boot sound, as well as decode it. Set begin Option Item Audio setting ˜duration 0AH ¯ appendix A(00-10H) Duration setting ˜default 05H ¯...
  • Page 18: String Character Setting

    2.4 String (character) setting Prefix ˆsuffix string setting A max. of 10 ASCII characters could be added before or after the bar code data ˜No action can be done if it is set to 0. Format as follow Prefix string Bar code data Suffix string...
  • Page 19 Check the table of ASCII ¨Look for the ASCII value of the corresponding insert location ˜ Scan the end bar code through appendix A ˜ Repeat the same steps for inserting G2 group character location ˜ Scan end set up Send barcode If your application needs to send code (bar code type of ID), you must set the format ON : ID + barcode information.
  • Page 20 Set begin Option Item Set prefix characters ˜default 00 ¯ See appendix A Set suffix characters ˜default 00 ¯ See appendix A ˜default 00 ¯ G1Insert character See appendix A G2Insert character ˜default 00 ¯ See appendix A G1Insert character location See appendix A ˜default 00 ¯...
  • Page 21: Other Settings

    2.5 Other setting Scan accuracy Can be set to scan once or twice then transmit bar code ¨it could be set to twice in order to reduce errors. Bar level setting Input level to set up through the bar signals ¨ noted that level must match in order to decode ˜...
  • Page 22 Chapter 3 Bar code option Read When the selection is on ¨ such bar code can be decode ¨as well as transmitted ¨or couldn’t be read nor transmitted ˜ Set code Necessary type of barcode ID could be set ¨ the “send code”...
  • Page 23: Upc-A

    supplementary code ¨ you need to select setting according to the type of supplementary code needed. Truncate pre-0 : delete the bar code before the 0. 3.1UPC-A Parameter setting UPC-A convert to EAN-13 To convert UPC-A to EAN-13 ¨add 0 in front of the bar code data Set begin Option Item...
  • Page 24 Set begin Option Item OFF ˜default ¯ Truncate pre-0 Before median cut-off appendix (default:00) A(00-0DH) After median cut-off appendix (default:00) A(00-0DH) Insert group selection appendix (default:00) ˜00-02H ¯ None (default) Supplementary code 2digits reader 5 digits 2 or 5digits - 24 -...
  • Page 25 End set up 3.2UPC-E Parameter setting UPC-E convert to UPC-A converting 8-digts UPC-E to 12-digits UPC-A Set begin Option Item Read ON(default) Set code (default G) appendix A(20-7EH) OFF(default) UPC-E convert to UPC-A Send check ON(default) Before median cut-off (default:00) appendix A(00-08H) - 25 -...
  • Page 26 Set end Set begin Option Item After median cut-off (default:00) appendix A(00-08H) Insert group selection (default:00) appendix A(00-02H) Truncate pre-0 ON(default) None(default) Supplementary code 2digits reader 5digits 2 or 5 digits Set end - 26 -...
  • Page 27 3.3 EAN-13 Parameter setting Set begin Option Item Read ON(default) Set code (default:H) appendix A(20-7EH) Send check code ON(default) Before median cut-off appendix (default:00) A(00-0DH) After median cut-off appendix (default:00) A(00-0DH) Set end - 27 -...
  • Page 28 Set begin Option Item None(default) Supplementary code reader 2digits 5digits 2 or 5digits ISBN/ISSN conversion OFF (default) Insert group selection appendix (default:00) A(00-02H) Set end - 28 -...
  • Page 29 3.4 EAN-8 Parameter setting Set begin Option Item Read ON(default) Set code appendix (default:I) A(20-7EH) Send checksum characters ON(default) Before median cut-off (Default:00) appendix A(00-08H) Set end - 29 -...
  • Page 30 Set begin Option Item (default:00) After median cut-off digit appendix A(00-08H) None(default) 2digits Supplementary code reader 5digits 2 or 5digits Insert group selection (default:00) appendix A(00-02H) Set end - 30 -...
  • Page 31: Code 39

    3.5 Code39 Parameter setting Set begin Option Item Read ON(default) Set code (default:J) appendix A(20-7EH) OFF(default) Check Send checksum characters ON(default) Set end - 31 -...
  • Page 32 Data tandem Code39 Format: The wholeASIICode39 are enhanced 39code ¨which included a total of 128characters ¨ corresponding to 128 ASCII code ˜ CODE 32 Read Open to read CODE 32 Set begin Option Item OFF(default) Data tandem Min. length (default:00) appendix A(00-32H) Max.
  • Page 33 Set begin Option Item OFF (default) Send start / End character Before median cut-off (default:00) appendix A(00-32H) After median cut-off (default:00) appendix A(00-32H) Insert group selection (default:00) appendix A(00-02H) End set up - 33 -...
  • Page 34: Codabar

    3.6 Codabar Parameter setting Set begin Option Item Read ON(default) Set code(default :K) appendix A(20-7EH) Check ON(default) OFF(default) Send checksum character OFF(default) Data tandem Set end - 34 -...
  • Page 35 Set begin Option Item Before median cut-off (default:00) appendix A(00-7EH) After median cut-off (default:00) appendix A(00-7EH) ABCD/ABCD(default) Send start / End character abcd/abcd abcd/tn*e OFF(default) Send start / End character Min. length(default:00) appendix A(00-3CH) Max. length(default: 3CH) appendix A(00-3CH) Insert group selection (default:00) appendix A(00-02H)
  • Page 36: Code 93

    Set end 3.7Code93 Parameter setting Set begin Option Item Read ON(default) Set code appendix (default:L) A(20-7EH) Check ON (default) Set end - 36 -...
  • Page 37 Set begin Option Item Send checksum OFF( default ) characters Min. length appendix ( default :00) A(00-50H) Max. length ( default :00) appendix A(00-50H) Before median cut-off ( default :00) appendix A(00-7EH) After median cut-off appendix ( default :00) A(00-7EH) Insert group selection appendix A(00-02H)
  • Page 38 3.8Code 128 Parameter setting Set begin Option Item Read ON ( default ) Set code appendix ( default :M) A(20-7EH) Check ON( default ) OFF( default ) Send checksum characters Insert group selection appendix ( default :00) A(00-02H) Set end - 38 -...
  • Page 39 Set begin - 39 -...
  • Page 40 Option Item OFF( default ) FNC2 tandem OFF( default ) UCC/EAN128 OFF( default ) Send FNC1 Before median cut-off appendix ( default :00) A(00-7FH) After median cut-off appendix ( default :00) A(00-7FH) Min. length ( default :00) appendix A(00-7FH) Max. length appendix (default:7FH) A(00-7FH)
  • Page 41: Interleaved 2 Of 5

    3.9 Interleaved 2 of 5 Set begin Option Item Read ON(default) Set code appendix (default:N) A(20-7EH) OFF(default) check Send checksum characters ON(default) Set end - 41 -...
  • Page 42 Set begin Option Item Before median cut-off appendix (default:00) A(00-7EH) After median cut-off (default:00) appendix A(00-7EH) Min. length (default:00) appendix A(00-7FH) Max. length appendix (default:7FH) A(00-7FH) Insert group selection appendix (default:00) A(00-02H) Set end - 42 -...
  • Page 43: Industrial 2 Of 5

    3.10 Set begin Industrial 2 of 5 Parameter setting Option Item OFF(default) Read Set code (default:O) appendix A(20-7EH) Min. length (default:00) appendix A(00-32H) Max. length appendix (default:32H) A(00-32H) Set end - 43 -...
  • Page 44 Set begin Option Item Before median cut-off (default:00) appendix A(00-32H) After median cut-off (default:00) appendix A(00-32H) OFF(default ¯ Check OFF(default) Send checksum characters Insert group selection appendix (default:00) A(00-02H) Set end - 44 -...
  • Page 45: Matrix 2 Of 5

    3.11 Matrix 2 of 5 Parameter setting Set begin Option Item OFF (default) Read Set code (default:P) appendix A(20-7EH) OFF (default) Check Set end - 45 -...
  • Page 46 Set begin Option Item Send checksum characters ON(default) Before median cut-off appendix (default:00) A(00-50H) After median cut-off appendix (default:00) A(00-50H) Min. length (default:00) appendix A(00-50H) Max. length (default:50H) appendix A(00-50H) Insert group selection appendix A(00-02H) - 46 -...
  • Page 47: China Post Code

    Set end 3.12 China post code parameter setting Set begin Option Item OFF (default) Read Set code appendix (default:Q) A(20-7EH) OFF(default) Check OFF(default) Send checksum characters Set end - 47 -...
  • Page 48 Set begin Option Item Before median cut-off (default:00) appendix A(00-50H) After median cut-off (default:00) appendix A(00-50H) Min. length appendix (default:00) A(00-50H) Max. length appendix (default:50H) A(00-50H) Insert group selection appendix (default:00) A(00-02H) Set end - 48 -...
  • Page 49: Msi/Plessey

    3.13 MSI/Plessey Parameter setting Set begin Option Item OFF(default) Read Set code (default:R) appendix A(20-7EH) OFF (default) MOD 10 Check MOD 10/10 MOD 11/10 Set end - 49 -...
  • Page 50 Set begin Option Item Send checksum characters ON (default) Before median cut-off appendix (default:00) A(00-3CH) After median cut-off appendix (default:00) A(00-3CH) Min. length appendix (default:00) A(00-3CH) Max. length (default:3CH) appendix A(00-3CH) Insert group selection (default:00) appendix A(00-02H - 50 -...
  • Page 51: Code 32

    Set end 3.14 CODE 32 Parameter setting Set begin Option Item OFF ˜default ¯ Read Setting code (default :R) See appendix A(20-7EH) Check ON ( default) Send parity bit ON ˜default ¯ Set end - 51 -...
  • Page 52 Set begin Option Item Before median cut-off (default:00) See appendix A(00-0AH) After median cut-off (default:00) See appendix A(00-0AH) Insert group selection (default:00) See appendix A(00-02H) Set end - 52 -...
  • Page 53: Code 11

    3.15 Code 11 Parameter setting Set begin Option Item OFF(default) Read Install code (default:T) appendix A(20-7EH) check ON (default) Set end - 53 -...
  • Page 54 Set begin Option Option OFF(default) Send checksum characters Before the median cut-off appendix (default:00) A(00-50H) After the median cut-off appendix (default:00) A(00-50H) Min. length (default:00) appendix A(00-50H) Max. length (default:50H) appendix A(00-50H) Insert group selection (default:00) appendix A(00-02H - 54 -...
  • Page 55 Set end - 55 -...
  • Page 56 Appendix A ASCII barcode end set up - 56 -...
  • Page 57 Table of ASCII “ NAK % ACK SYN & ‘ SUM * < > - 57 -...
  • Page 58 Appendix B Table of function key emulation NULL DOWN LEFT RIGHT PAGE UP PAGE DOWN HOME ENTER INSERT DELETE - 58 -...
  • Page 59 Function key emulation barcode Before scanning the barcode ¨ turned ON the multi-featured function CODE 39 ‰ UP($A) F1($Q) DOWN($B) F2($R) LEFT($C) F3($S) RIGHT($D) F4($T) PAGE UP($E) F5($U) PAGE DOWN($F) F6($V) F7($W) BS($H) F8($X) TAB($I) F9($Y) - 59 -...
  • Page 60 F10($Z) HOME($K) ESC(%A) END($L) F11(%B) ENTER($M) F12(%C) INSERT($N) F13(%D) DELETE($O) F14(%E) - 60 -...