➤ Route the condensation hose along the refrigerant hoses to the evaporator.
➤ Guide the condensation hose outside through the base of the vehicle, so that
the condensate is discharged.
➤ Connect the fan and the temperature sensor in accordance with the circuit
diagram (fig. f, page 11, fig. g, page 11 and supplementary sheet).
I
NOTE
Ensure that the connection cables are inside the cover when installing the
evaporator cover.
➤ Attach the cover
– with 4 x bolts for Frigo DC 2500 or
– with 6 x bolts for Frigo DC 3500.
➤ Connect the condensation hose to the cover with the hose clamp 10 – 16
(fig. l, page 14).
➤ Attach the sticker.
9.5.4
Connecting cables to the DC unit
Proceed as illustrated (fig. m, page 14):
➤ Route the refrigerant hoses under the vehicle to the DC unit.
➤ Route the extension cable under the vehicle to the DC unit.
➤ Connect the refrigerant hoses.
➤ Connect the extension cable.
➤ Route the connection cable of the DC unit to the vehicle's battery.
9.5.5
Connecting the transport refrigeration system to the battery
➤ Connect the connection cable for the DC unit to the battery in accordance
with the circuit diagram (fig. f, page 11, fig. g, page 11 and supplemen-
tary sheet).
➤ Mount the fuse supports as illustrated (fig. n, page 15).
➤ Connect the earth connections to the vehicle chassis.