TapFlo DT Series Instructions For Installation, Operation And Maintenance

TapFlo DT Series Instructions For Installation, Operation And Maintenance

Active pulsation dampeners
Hide thumbs Also See for DT Series:

Advertisement

Quick Links

Instructions for installation, operation and maintenance for active pulsation dampeners.
New DT Series.
Active pulsation dampeners
models:
DT 9/20/25
DT 50/70/80
DT 100/120/125
DT 200/220/225
DT 400/420/425
DT 800/820/825
Read this instruction manual carefully,
STOP
before you install and operate the pump

Advertisement

Table of Contents
loading

Summary of Contents for TapFlo DT Series

  • Page 1 Instructions for installation, operation and maintenance for active pulsation dampeners. New DT Series. Active pulsation dampeners models: DT 9/20/25 DT 50/70/80 DT 100/120/125 DT 200/220/225 DT 400/420/425 DT 800/820/825 Read this instruction manual carefully, STOP before you install and operate the pump...
  • Page 2: Table Of Contents

    CONTENTS GENERAL 0.1. Introduction 0.2. Warning symbols INSTALLATION & SAFETY 1.1. Receiving inspection 1.2. Storage 1.3. Installation of the dampener 1.4. Operation principal 1.5. Health & Safety 1.5.1. Protection 1.5.2. Explosion hazardous environments – ATEX 1.5.3. Air pressure 1.5.4. Noise level 1.5.5.
  • Page 3 CE CERTIFICATE Declaration of conformity Machinery directive 2006/42/EC AB declares that: Active Pulsation Damener Product name: D T… Models: Is in conformity with the essential health and safety requirements and technical construction requirements of the EC Machinery directive 2006/42/EC. Manufacturer: Address: Filaregatan 4 S-442 34 Kungälv...
  • Page 4: General

    The active pulsation dampener is the most efficient way to remove pressure variations on the discharge of the pump. The Tapflo pulsation dampener works actively with compressed air and a diaphragm, automatically setting the correct pressure to minimise the pulsations. The pulsation dampener is available for all Tapflo pump sizes and material versions.
  • Page 5: Installation & Safety

    INSTALLATION & SAFETY Receiving inspection Although precaution is taken by us when packing and shipping, we urge you to carefully check the shipment on receipt. Make sure that all parts and accessories listed on the packing list are accounted for. Immediately report any damage or shortage to the transport company and to us. Storage If the equipment is to be stored prior to installation, place it in a clean location.
  • Page 6: Operation Principal

    The dampener must be installed according to local and national safety rules. STOP The dampeners are constructed for particular applications. Do not use the dampener on applica- tions different from that for which it was sold without consulting Tapflo AB to ascertain its suitability. IOM manual Active pulsation dampeners...
  • Page 7: Protection

    1.5.3. Air pressure The maximum air pressure for Tapflo dampeners is 14 bar. Higher air pressure than 14 bar can STOP damage the dampener and may cause injury to personnel in vicinity of the dampener.
  • Page 8: Maintenance

    MAINTENANCE 2.1. When dampener is new or re-assembled If the dampener is new or re-assembled after maintenance it is important to re-tighten the dampener housing screws (pos. 37) after a few days of operation. Make sure to use the right torque, see chapter 4.2.
  • Page 9 MAINTENANCE Fig. 2.4.3. Using two spanners unscrew the nuts [37] cross-side and take them out alongside with the washers [38]. Fig. 2.4.4. Take out the dampener block [12]. Fig. 2.4.5. Take the pin screws [14] out of the dampener housing [11]. Fig.
  • Page 10: Assembling The Dampener

    MAINTENANCE Fig. 2.4.9. Check the inner seals [36] and O-rings [47]. If necessary, take them out using a screwdriver. Note! If these parts are removed, they must be replaced with new ones. If the dampener sealing is worn, also check the shaft for wear and if necessary replace it.
  • Page 11 MAINTENANCE Fig. 2.5.4. Screw the shaft ending [1652] into the diaphragm [15]. Note! It is very important to screw the shaft ending(using an allen key) as deep as possible so it won’t have the tendency to unscrew during operation. Fig. 2.5.5. Screw the diaphragm [15] with the shaft ending [1652] onto the shaft [1651].
  • Page 12 MAINTENANCE Fig. 2.5.10. Insert the washers [38] and nuts [37] on the pin screws [14] from the side of the block and pre-tighten the nuts cross side. Fig. 2.5.11. Tighten the nuts [37] cross-side by means of a torque wrench with the appropriate torque (see chapter 4.2.).
  • Page 13: Spare Parts

    SPARE PARTS Spare parts drawing – PE, PTFE and aluminium 1651 1652 71/73 1173 1181 Spare parts list – PE, PTFE and aluminium DESCRIPTION QUANTITY Dampener housing Threaded insert 1173 Reinforcement plate 1 *** 1181 Cover 1 *** Dampener block Pin screw 4 / 6 / 8 * Diaphragm...
  • Page 14: Spare Parts Drawing - Steel And Sanitary

    SPARE PARTS Spare parts drawing – steel and sanitary 1651 1652 Spare parts list – steel and sanitary DESCRIPTION QUANTITY Dampener housing Dampener block Pin screw 4 / 6 / 8 * Washer 4 / 6 / 8 * Diaphragm 1651 Shaft 1652...
  • Page 15: Recommended Spare Parts

    1 How to order parts When ordering spare parts for Tapflo dampeners, it will simplify the process if you give the model and serial number from the nameplate of the dampener, position number of the part and quantity. IOM manual Active pulsation dampeners...
  • Page 16: Technical Data

    TECHNICAL DATA Dimensions PE, PTFE and aluminium dampener Steel and sanitary dampener Dimensions in mm (where other is not indicated) Dimensions in inch (where other is not indicated) PE / PTFE ALU / SS ISO 2852, DIN 11851, SMS1145, BS 4825 (RJT) Dimensions for other connections in next table IOM manual Active pulsation dampeners...
  • Page 17: Tightening Torques

    Tightening torques DAMPENER SIZE TIGHTENING TORQUE [Nm] DT 9/20/25 DT 50/70/80 DT 100/120/125 DT 200/220/225 DT 400/420/425 DT 800/820/825 Dampener code Tapflo active pulsation Tapflo pump size (l/min) Material of wetted dampener dampener housing: Aluminium Polyethylene Stainless steel AISI 316 PTFE T - 3APL Special execution:...
  • Page 18: Warranty & Repair

    Goods will not be accepted unless the above procedure has been complied with. Warranty Tapflo warrants products under conditions as stated below for a period of not more than 12 months from installation and not more than 24 months from date of manufacturing.
  • Page 19 Tapflo in written within the mandatory term of 8 days from the discovery. Repair or replacement under the terms of this warranty shall not give a right to an extension to, or a new commencement of, the period of warranty.
  • Page 20: Warranty Form

    WARRANTY & REPAIR Warranty form Company: Telephone: Fax: Address: Country: Contact name: E-mail: Delivery date: Dampener was installed (date): Dampener type: Serial No (stamped on the dampener housing): Description of the fault: The installation Liquid: Temperature (°C): Viscosity (cPs): Spec. grav. (kg/m pH-value: Contents of particles: %, of max size (mm):...
  • Page 21 NOTES IOM manual Active pulsation dampeners...