  • Page 1 GE D igital E nergy Power Quality Z enith ZTS S eries Low-Voltage Automatic and Manual Transfer Switches...
  • Page 2 • UL 1008 listed for Short Time rated 1600-3000A (Non-bypass) ATS for 0.50 sec and 1.0 sec time duration Speci cation Assistance GE o ers a complete range of product guide speci cations to help you determine your needs. For more information, please consult your local GE representative, our factory or our website at www.gepowerquality.com.
  • Page 3 Zenith ZTS Series Automatic Transfer Switches The Zenith ZTS Series is the building block of our transfer switch Neutral Switching product line. This ruggedly built power contactor family of switches The Zenith ZTS Series is available in true four pole designs for has been specifically designed for transfer switch duty with multi-source power systems that require neutral switching.
  • Page 4 MX 250 Series Microprocessor Controller Enhanced Display and Settings LED s are used in a recognizable line configuration for continuous monitoring of switch position. The LCD display shows source availability, exercise time delay operation and system source condition. A simplified adjustment is featured for voltage, frequency and time delay settings.
  • Page 5 Z enith ZTS Series Accessory De nitions Z enith ZTS Series Accessory Group Matrix Group Packages Accessories MSTD MEXE MCON MSEN MSPE MPSG Microprocessor activated test switch (Momentary) Hardwired test switch (Maintained) 6 AP Microprocessor activated test switch (Maintained) Calibrate Hardwired test switch (Maintained Auto - Momentary Test) **DS Key operated...
  • Page 6 Z enith ZTS Series Accessory De nitions (cont.) ZNET901A R 15/ R 15 D Modbus Annunciator Load Shed. Should Source 2 become overloaded, an external signal can be given to ATS to transfer to the Neutral or dead Normal (Source 1) position. Single Phase Amp Meter (Analog) R 16 Three Phase Amp Meter (Analog)
  • Page 7 UMD, Digital Meter, HT, HH, K, LDS, L11, N1, N2, OCVR-1SG, OCVR-1SS, P2, SPD, BCI, R26(D). Please contact the GE factory for dimensions. 12. For Delayed and Closed Transition dimensions and weights, refer to GE Publication PB -5067 and PB -5069.
  • Page 8: Switch Types