Summary of Contents for DAB DTRON2 35/90

  • Page 1 ‫اﻟﺸﻜﻞ‬ Fig. - Fig. – Image - Abb. - Afb. – Fig. - Рис. - Obr. – Kuva – Fig. – Fig. – Εικ. – Şekil – Rys. – Ábra – Fig. – Фиг. - Fig.1 Fig.2 Fig.3 Fig.5...
  • Page 2 Fig. 6 Fig. 7 Fig.9 Fig.8...
  • Page 3 Fig.10 Fig.11...
  • Page 4: Table Of Contents

    ENGLISH CONTENTS WARNINGS ......................................8 RESPONSIBILITY ....................................9 GENERAL ..................................... 9 Applications ..................................9 Pumpable Liquids ................................10 Technical Data ................................... 10 INSTALLATION................................... 11 Mechanical Installation ..............................11 FIRST INSTALLATION ................................12 FUNCTION ....................................13 Pump start and stop conditions ............................13 Pump On –...
  • Page 5: Responsibility

    ENGLISH The power supply cable and the float switch must never be used to carry or lift the pump. Always use the pump handle. Use is allowed only if the electric system is in possession of safety precautions in accordance with the regulations in force in the country where the product is installed (for Italy CEI64/2).
  • Page 6: Pumpable Liquids

    ENGLISH These pumps cannot be used in swimming pools, ponds or basins where people are present, or for pumping hydrocarbons (petrol, diesel fuel, combustible oils, solvents, etc.) in accordance with the accident-prevention regulations in force. They should be cleaned before putting them away (See chapter “Maintenance and Cleaning”). Pumpable Liquids Only use the pump in clean water.
  • Page 7: Installation

    ENGLISH Pos. Description Description Revision Year Week Serial number Maximum liquid temperature Flow rate Maximum head Minimum head Insulation class Degree of protection Submersibility Rated voltage Ampere P2 HP P2 kW Frequency Fig.4 Data plate Condenser capacity Voltage Rated number of revolutions Logos Pump code INSTALLATION...
  • Page 8: First Installation

    ENGLISH The pump is suitable for vertical or horizontal installations. Connect a rigid or flexible pipe to the 1¼” delivery of the pump. The maximum submersibility of the pump depends on the length of the power cable: 12m (39.4 ft) in the case of a cable 15m (49.2 ft) long; 7m (23 ft) in the case of a cable 10m (32.8 ft) long.
  • Page 9: Function

    ENGLISH FUNCTION The electronics automatically control starting and stopping (ON/OFF) of the pump depending on the request for water. The electronics protect the pump from faults in the Non Return Valve (NRV) in the pump casing, which are generally caused by dirt or sand deposits.
  • Page 10: Cleaning Storage Maintenance

    ENGLISH • From the 1st to the 48th attempt: 1 restart every 30 minutes for 20 seconds each • From the 49th attempt: 1 restart every 24 hours for 20 seconds each  The DRYRUN alarm can be reset manually: if after this reset the pump still does not detect flow and pressure, attempts will last 20 seconds.