La Cornue 75LCI18 Installation Instructions & Use & Care Manual

La Cornue 75LCI18 Installation Instructions & Use & Care Manual

Insert series for wall hoods

Advertisement

Quick Links

***ATTENTION***
PLEASE REMOVE THE
RIGHT SIDE BAFFLE
FILTER TO LOCATE YOUR
NEW REMOTE CONTROL.
Revised 3/27/20
Copyright © 2020 La Cornue
Page 1

Advertisement

loading

Summary of Contents for La Cornue 75LCI18

  • Page 1 ***ATTENTION*** PLEASE REMOVE THE RIGHT SIDE BAFFLE FILTER TO LOCATE YOUR NEW REMOTE CONTROL. Revised 3/27/20 Copyright © 2020 La Cornue Page 1...
  • Page 2 Revised 3/27/20 Copyright © 2020 La Cornue Page 2...
  • Page 3 Please keep Installation Instructions for local electrical inspector’s use and for future reference. Owner: WARNINGS: Must be followed carefully to avoid personal injury. IMPORTANT: Must be followed carefully to avoid damage or incorrect installation. TIPS: Contain helpful information to facilitate installation. Revised 3/27/20 Copyright © 2020 La Cornue Page 3...
  • Page 4 3. The ducting must be air tight. Use a minimum of 2 sheet metal screws at every duct joint. Then, seal the duct joints with high quality duct tape. 4. Do not use this unit with any solid-state speed control device. 5. This unit must be grounded. Revised 3/27/20 Copyright © 2020 La Cornue Page 4...
  • Page 5 PART 1 Planning the Installation La Cornue Insert Series for Wood Hoods are designed for installation inside custom hood canopies. Proper installation of the Insert is directly related to the material from which the custom canopy is constructed. A qualified person must complete the installation of this unit.
  • Page 6 2. Damper not included. (No Vent Transition Needed) ” larger than above 3. Length & width cutouts should be ” larger than above 3. Length & width cutouts should be dimensions. dimensions. Revised 3/27/20 Copyright © 2020 La Cornue Page 6...
  • Page 7 2. Damper not included. (No Vent Transition Needed) ” larger than above 3. Length & width cutouts should be ” larger than above 3. Length & width cutouts should be dimensions. dimensions. Revised 3/27/20 Copyright © 2020 La Cornue Page 7...
  • Page 8 CONNECTING TO THE VENT PIPE The La Cornue Insert Series for Wood Hoods comes with a metal start collar welded in place. Attach the Start Collar to the duct with at least three equally spaced screws. Also apply duct tape, preferably the metal type.
  • Page 9 LED LIGHT BULBS: La Cornue Insert Series for Wood Hoods are designed for MR16/GU10 LED flood light bulbs. They can be purchased at most home or grocery stores. The bulbs provided with the unit are 3.5 watt, 350 lumens, and 3000K (warm white color temperature).
  • Page 10 (either in-line or roof top). If the ventilator is rated in watts rather than amps, divide the watts by 120 and this will give you the amperage rating. The La Cornue Insert Series for Wood Hoods, without the internal motor, is supplied with a 6.0 amp variable speed fan control.
  • Page 11 120V Black Liner IMPORTANT: La Cornue does not pay warranty claims for damage to Inserts or components connected to other brand blowers inconsistent with these Installation Instructions. Always consult the switch manufacturer's installation instructions when substituting control switches. The warranty may be voided if any unauthorized service, alterations or repairs are made to the product.
  • Page 12 La Cornue has a policy of continuous improvements and reserves the right to modify (at any time and without notice) any or all of its products, features, designs, components and specifications. For exact dimensions, see the Installation Instructions included with each product Some features may be slightly different than shown on product literature.
  • Page 13 As previously mentioned, improperly installed duct pipe will cause excessive static pressure (air resistance), that may result in rattling, vibration and air buffeting noises, as well as inadequate ventilation. Revised 3/27/20 Copyright © 2020 La Cornue Page 13...
  • Page 14 In his position, gravity will help close the damper blades after each use. Otherwise, because of gravity, the damper’s blades will not close and the damper will not prevent backdrafts. Revised 3/27/20 Copyright © 2020 La Cornue Page 14...
  • Page 15 The “radius” is one-half the diameter of a round duct, e.g., ½ of a 10” round duct is 5”. 3.1416 is “Pi”, the “constant” used when calculating the area of a circle. Revised 3/27/20 Copyright © 2020 La Cornue Page 15...