TABLE OF CONTENTS WP-250 Service Manual ................1 General Maintenance ................1 Ribbon Replacement ................1 Removing Old Ribbon ..............1 Installing New Ribbon ..............1 Description and Location of Major Components ......... 2 Time and Date Option ................2 Installing Time and Date Option ............
WP-250 Service Manual The WP-250 Ticket Printer is designed to operate with a minimal amount of General regular maintenance. However, it is important that the printer remain clean Maintenance during operation. The most critical part to be kept clean is the head shaft. The shaft should be cleaned and fresh lubricant lightly applied two or three times a year.
Installing Time and the WP-250, the option was probably purchased and installed before the Date Option unit was shipped. If you purchased the WP-250 without the options, it can be easily installed: 1. Unplug the printer from the wall outlet.
The BCD Option is used to interface electronic weigh scales that have only BCD Interface Option a BCD type interface. Parallel BCD is not a general data interface and does not use the ASCII control codes. It is a numeric interface meant to obtain the weight, units, and motion indication from electronic weigh scales.
Installing The BCD the WP-250, the option was probably purchased and installed at the Interface Option factory. If you purchased the WP-250 without the option, it can be easily installed. 1. Unplug the printer from the wall outlet. 2. Program the 8 Position DIP Switch in the BCD Module.
+ RS-485 - RS-485 Current Loop The 20 mA Current Loop, which is standard in the WP-250, is a good interface for systems that will require long distances between the host device and the printer. Data is sent between the transmitter and receiver as a series of pulses.
It does not matter which side is passive and which is active as long as there is only one of each. The WP-250 has the hardware needed to be the passive side of the 20 mA interface for the receive loop.
Missing dots are caused by 1 or more of the following: Missing Dot Troubleshooting 1. Broken needle 2. Blown transistor 3. Blown drive diode 4. Blown fuse The table below lists the dot driver components in order of dot position. If a dot is missing, check ALL of the dot driver components for the missing dot.
Print Head Mechanism Replacement/Alignment Procedure 1. Remove power from the printer, then remove the ribbon. Removal of Print Head 2. While looking at the printer from the front, loosen the two screws on Carrier Assembly the left side of the print head assembly, then remove the two screws on the right side.
Replacement of Assembly 1. Replace the dot head unit on the print head carrier assembly as follows: 1a. Screw the dot head unit together with the ribbon guide assembly (B) to the print head carrier assembly. Tighten the screws. CPW: M4 x 8 (2 pieces metric) 1b.
Need help?
Do you have a question about the WP-250 and is the answer not in the manual?
Questions and answers