Replacement Steps - Water Filters
It is recommended that the #1 sediment filter
and #2 RO filter be replaced at least once per
season or as needed.
Do not replace the #3 staging tank. At the end
of the humidification season, unscrew the #3
filter and empty any remaining water.
When installing new filters, install #2 RO filter
first, followed by the #1 sediment filter.
NOTE: Periodically check the flow control to be
sure the small hole through it is clean
and unrestricted. If the flow control
requires service, remove and replace the
cylindrical plastic flow control that is
inserted into the elbow connector. If the
flow control remains in the manifold
when the elbow connector is removed,
you will need to remove the drain ports
collar and O-ring to retrieve it.

MAINTENANCE

Sediment Filter
Turn cartridges in the direction of
the arrow to remove. Turn them
in the opposite direction to install.
NOTE: Refer to the steam humidifer's manual for
7
#1
Replace
Replace
more detailed maintenance steps.
#3
Staging Tank
#2
RO Filter
Remove,
empty and
reconnect
FIG. 6