  • Page 1 DSE4200 Installation guide Document No.: D3702-019 Version: 02.01.01 29 April 2020 ©DSE Test Solutions A/S...
  • Page 2: Table Of Contents

    2.2.5 Step 5............................ 9 2.2.6 Step 6..........................10 2.2.7 Step 7..........................10 TROUBLESHOOTING ...................... 10 WIRING OF DSE4200 IN BALER AND TRACTOR ............11 SCHEMATICS OF DSE4200 CABLE SET ............... 12 Version history Version Date Prep. Status App.
  • Page 3: General Data

    Cable from Display to TX and Power source. (-W1, -W2) DSE4200 USB memory stick 2.2 Installation For overview of the installation, refer to Chapter 4 “Wiring of DSE4200 in Baler and Tractor.” The installations process is relatively simple, and the best result is achieved by following these steps.
  • Page 4: Step 1

    Moisture Meter, as shown on the drawing below. The protection plate is considered a wearing part and needs to be replaced from time to time when worn out. This protection plate need to be in a material transparent for microwaves. This is delivered on request from DSE Test Solutions as accessories.
  • Page 5 This can be done by adding washers or spacers. DSE Test Solutions doesn’t deliver the mounting brackets for mounting in the baler channel, as those needs to be individual for different baler models.
  • Page 6 DSE4200 Installation guide Example 2: The picture below shows the inside of the channel. The metal strip welded to the wall before the TX/RX unit minimizes buildup of material around the TX/RX units that might damage them. ©DSE Test Solutions A/S,...
  • Page 7: Step 2

    DSE4200 Installation guide 2.2.2 Step 2. The proximity switch is mounted at the tips of the star wheel as illustrated on the pictures. Fasten with bracket included. Attach the cable as illustrated and connect to the Moisture Meter. Adjust the distance between the proximity switch and the teeth of the star wheel to approx.
  • Page 8: Step 3

    DSE4200 Installation guide 2.2.3 Step 3. Insert the plugs in the Moisture Meters and connect by pulling and securing the cable underneath the channel. 2.2.4 Step 4. Draw the cable from the moisture meter to the front end of the baler. Make sure the cables are drawn in a way that protects the cables in the best possible way, and keep the cables safe from moving parts on the baler.
  • Page 9: Step 5

    NB: To ensure that the DSE4200 does not drain the battery when the tractor is not running, connection must be made to a switched power source.
  • Page 10: Step 6

    DSE4200 Installation guide 2.2.6 Step 6. Connect the plugs as illustrated. NB: These 7 pin trailer connectors are for DSE4200 use only and must not be connected to other equipment than DSE4200 or damage may occur. 2.2.7 Step 7. Turn on the display and follow the installation procedure for parameter set up and Zero Adjust.
  • Page 11: Wiring Of Dse4200 In Baler And Tractor

    DSE4200 Installation guide 4. Wiring of DSE4200 in baler and tractor NB: Always connect DSE4200 to switched power (ACC), not directly to battery as shown in cable schematics ©DSE Test Solutions A/S, 11 of 12 29 April 2020 Project no.: 3702 Document no.: D3702-019...
  • Page 12: Schematics Of Dse4200 Cable Set

    DSE4200 Installation guide 5. Schematics of DSE4200 cable set ©DSE Test Solutions A/S, 12 of 12 29 April 2020 Project no.: 3702 Document no.: D3702-019 Version no.: 02.01.01...