Download Print this page

Yamaha Electone GX-1 Service Manual page 141

Hide thumbs Also See for Electone GX-1:

Advertisement

GX-1
(S/#
5030~
)
34. Foot Switch
SUB OSCILLA-
TOR
CANCEL
UPPER
LOWER
RHYTHM STOP
SOLO
PORTAMENTO
*With the foot switch selector switch at '1', when the foot switch
is set from "0" to "1" the lamp lights.
*With the lamp lit, panel 4 sub oscillator VCF, VCA, VCO
are all on
and panel 5 VCF, VCA, VCO and speed tablets are all off.
*With the switch at ''1'', the lamp can be switched on and off by the
foot switch.
*When the switch is at ''0'', the lamp is off.
*Works the same as the above, except that it affects the panel 6 and 7
levers and tablets.
*When the rhythm section is being used and the foot: selector switch
for rhythm
is at ''1'', moving the foot switch from "0" to "1" will
stop the rhythm.
*The
foot
switch
can
be used to push for on, push again for off.
*With the foot selector switch for solo portamento set at ''1'' and the
panel 3 solo portamento
lever at ''3'', when the solo keyboard C3
and C6 are pressed in turn, no effect will be heard if the foot switch
is at '0'.
But once it is set to '1', the portamento effect will be
heard.
The
position
of the panel
3 solo
portamento
knee lever
tablet ("0' or "'1'') has no effect in this case.