  • Page 1 MICROPROCESSOR TEMPERATURE CONTROLLER 1 8 l SERVICE MANUAL...
  • Page 2 SP 18L Manual Front panel description Controller view with marked functions 1. Turning on (hold ENTER button for 2 sec.). 2. LCD display. 3. Indicator lights. 4. Device control buttons. 5. Airflow start up indicator. 6. Central heating pump start up indicator. 7.
  • Page 3 2.Application The device is intended for controlling the boiler with automatic fuel feeding. The controller has an innovative controlling Logic system, the system operates on the basis of steady power control in the boiler. The devices automatically changes the airflow power and dispenses an adequate fuel amount so that the energy generated during the combustion process is used maximally.
  • Page 4 SP 18L Manual 4.Start-up and operation. STARTING UP THE DEVICE- Press and hold the key (ENTER). After starting up, a central heating and domestic hot water temperature is screened on the LCD display, the device starts to operate. 3 sec 20 C z 55 C 20 C z 45 C CHANGE OF MONITORING THE BOILER- Change of reading after...
  • Page 5 SP 18L Manual CHANGE OF THE DOMESTIC HOT WATER TEMPERATURE – Press the key ( ),the domestic hot water temperature is flashing on the display. Select the appropriate temperature,( )confirm by pressing the key (ENTER) 20 C z 55 C 20 C z 55 C 20 C z 55 C 20 C z 45 C...
  • Page 6 SP 18L Manual 5.Menu ENTERING THE MENU - Press the key (ENTER). The keys ( are intended for scrolling through the menu. Entering next sub-menu and confirming a selected parameter, press the key (ENTER). Exiting the menu, press the key (EXIT) Domestic hot water hysteresis. 20 C z 55 C Manual operation HSW hysteresis...
  • Page 7 SP 18L Manual The central heating pump works incessantly. While working in the domestic hot water priority mode, the adjuster maintains the temperature by 10ºC higher than the set one in the boiler in order to heat up rapidly the storage container. The domestic hot water priority function is equipped with the following safety functions: - lack of starting up the domestic hot water pump when the temperature of hot water storage container is higher than the temperature of the water...
  • Page 8 SP 18L Manual 6. Installation menu ENTERING THE INSTALLATION MENU – Simultaneously press and hold the keys ( ).The keys ( ) are intended for scrolling through the menu. Entering next sub-menu and confirming a selected parameter, press the key (ENTER). Exiting the menu, press the key (EXIT) 20 C z 55 C STAND-BY TIME...
  • Page 9 SP 18L Manual ximum rotational speed while starting. The parameter set in this way will allow to avoid any problems with the device for a long period of its use. - INDOOR ADJUSTER the device offers the possibility to connect an indoor thermostat responsible for maintaining the temperature within the rooms heated.
  • Page 10 SP 18L Manual MIN. BLOWER POW. MIN. BLOWER POW. MIN. BLOWER POW. MIN. BLOWER POW. MIN. BLOWER POW. MIN. BLOWER POW. MIN. BLOWER POW. - FUEL 1 Settings modification for the first fuel. - MAXIMUM FAN POWER the parameter is intended for determining a maximum fan rotational power (maximum boiler power) for the parameter 'first fuel'.The value of the maximum power is conventionally (99%) for eco-pea coal.
  • Page 11 SP 18L Manual is finished by confirming with the key ENTER and the maximum power test is then carried out. - MAXIMUM POWER TEST is aimed at determining an adequate fuel amount which will be burnt on the hearth in an optimal way! The fuel amount should be determined on the basis of an observation, if the fuel runs through as not fully burnt, its percent amount is decreased, but when the fuel runs out and the flame moves back to the feeder's pipe,...
  • Page 12 SP 18L Manual MAX. POWER TEST 40 C 35 / 85 Break time (s) Central heating temperature Feeding time (s) Caution! carrying out the tests, especially the maximum power test, one should allow the central heating system to receive the maximum amount of heat, since the boiler generates the maximum power while the test is in progress.
  • Page 13 SP 18L Manual 9. Errors Error 0 – Device failure. Error 1 – EEPROM memory failure. Error 2 – Central heating temperature sensor failure. Error 2 – Central heating temperature sensor failure. Error 3 – Domestic hot water temperature sensor failure. Error 4 –...
  • Page 14 SP 18L Manual 12. Electric parameters 1. Supply voltage ~ 230 V / 50 Hz 2. Power consumption (no ratings) 3. Output ratings: blower 100 W loader 100 W pumps 100 W 100 W...
  • Page 15 Producent: Electronics s.c. Paweł Wilgocki, Piotr Wilgocki ul. Moczydło 10a, 30-698 Kraków tel. 012 650 47 90, fax 012 650 47 91 e-mail: biuro@electronics.net.pl...