7.

Decommissioning

7.1

Place change

Procedure:
1. Disconnect electrical connection.
2. Disconnect pneumatic connection.
3. Dismantle the column switch and lean it at the side.
4. Follow what shown for first start up (see chap. 4.2).
5. Fix again the MS 65 OR RAC S80 with its 3 screws
on the pallet (see chap. 4.2).
i
In case of sale or transfer of MS 65 OR RAC S80, all
the documents included in the consignment volume
has to be integrally handed over together with the
equipment.
7.2

Temporary decommissioning

If the MS 65 OR RAC S80 is going to be stopped for a
limited period of time or if the equipment is not being
used for other reasons, always disconnect the network
plug from its socket!
It is suggested to clean accurately the
MS 65 OR RAC S80, also its tools and accessories, and
carry out a protection treatment (e.g. spraying of a thin
oil film).
7.3

Disposal

Disconnect the MS 65 OR RAC S80 from the mains
tension and take off the power supply cable.
Oil are water pollution risk fluids and have to be
disposed of in accordance with the rules in force.
Disassemble the MS 65 OR RAC S80, order the
materials according to the category it belongs to and
dispose of them according to the rules in force.
MS 65 OR RAC S80 complies to the rules of
the European directive 2002/96/CE (directi-
ve on the disposal of electrical and electro-
nic waste).
Electric and electronic devices which are out
of order, together with their cables, accesso-
ries, accumulators and batteries, have to be
disposed of separately from household waste.
For disposal of such products, use the
available return and collection systems.
The correct disposal of the
MS 65 OR RAC S80 makes it possible to
avoid environmental damage and to put at
no risk the life of people.
Beissbarth GmbH
Decommissioning | MS 65 OR RAC S80 | 19
8.

Technical data

8.1

MS 65 OR RAC S80

Function
Maximum noise level
Bead breaking cylinder force
Compressed air supply
Power supply tension
8.2

Dimensions and weights

Function
MS 65 OR RAC S80 (H x W x D)
Net weight
Gross weight
8.3

Reach

8.3.1

Car wheels

Function
Tire width
Maximum tire diameter
Rim diameter (internal locking)
Rim diameter (external locking)
8.3.2

Motorcycle wheels

Function
Tire width
Maximum tire diameter
Rim diameter
i
To operate on motorbike wheels it is necessary to
install the motorbike wheel connection device, avai-
lable upon request (see chap. 3.4).
en
Specifications
75 dB
25000N(2,5t)
8 – 12 bar
depending on the cho-
sen tension (see iden-
tification plate)
Specifications
1830 x 1860 x 1110 mm
217kg
245kg
min / max
3"– 12"
1000 mm
12"– 28"
10"– 26"
min / max
3"– 10"
1000 mm
15"– 28"
|
1 697 630 500
2013-03-05

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents