ELCOS DIM-807/00 Instruction And User's Manual

ELCOS DIM-807/00 Instruction And User's Manual

Irrigation close-coupled pump protection device

Advertisement

Quick Links

IRRIGATION CLOSE-COUPLED PUMP PROTECTION DEVICE
DIM-807/00
TYPE
THE CLOSE-COUPLED PUMP IS STOPPED
(VIA ELECTROMAGNET OR SOLENOID) IN CASES OF ANOMALY FOR:
• LOW COOLING LIQUID LIVEL
• INEFFICIENT BATTERY CHARGE ALTERNATOR (BELT BREAKAGE)
• LOW OIL PRESSURE
• OVERHEATING
• FUEL RESERVE (WITHOUT STOPPING ENGINE)
• INSUFFICIENT WATER PUMP PRESSURE
OIL AND BATTERY INDICATORS INTEGRATED INTO THE DEVICE
®
PARMA
ITALY
Tel. +39 0521/772021
Fax +39 0521/270218
GB DIM-807/00 /4
1
E-mail: info@elcos.it - HTTP://www.elcos.it

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DIM-807/00 and is the answer not in the manual?

Questions and answers

Summary of Contents for ELCOS DIM-807/00

  • Page 1 • LOW OIL PRESSURE • OVERHEATING • FUEL RESERVE (WITHOUT STOPPING ENGINE) • INSUFFICIENT WATER PUMP PRESSURE OIL AND BATTERY INDICATORS INTEGRATED INTO THE DEVICE ® PARMA ITALY Tel. +39 0521/772021 Fax +39 0521/270218 GB DIM-807/00 /4 E-mail: info@elcos.it - HTTP://www.elcos.it...
  • Page 2 NOT SUITABLE FOR USE AS A CRITICAL COMPONENT IN EQUIPMENT OR PLANTS RESPONSIBLE FOR KEEPING PERSONS OR OTHER LIVING BEINGS ALIVE YOUR ELECTRICAL TECHNICIAN CAN ASK US ANYTHING ABOUT THIS PROTECTION DEVICE BY TELEPHONING ONE OF OUR TECHNICIANS GB DIM-807/00 /4...
  • Page 3: Ignition Key

    Immediately for: After a 3-second delay for: - OIL PRESSURE SWITCH - COOLING LIQUID LEVEL PROBE - OVERHEATING THERMOSTAT - BATTERY CHARGE ALTERNATOR (ALTERNATOR BELT BREAKAGE) GB DIM-807/00 /4...
  • Page 4 This can be obtained by mounting a visual and/or acoustic indicator externally connected to the relevant output. This is continuously activated if the protections or fuel reserve alarm intervene. RESET: This is obtained by turning the ignition key to zero. GB DIM-807/00 /4...
  • Page 5 NORMALLY THE TIMER AT TIMER TERMINAL TIMED ZERO HORAS (INDICATED IN THE STOP FIGURE ALONGSIDE) TIMER WITH IS NEGATIVE SET HOURS WHEN THE HOURS TIMER ARE SET NOTE: WHEN THE TEST HAS BEEN COMPLETED RECONNECT THE PROBES GB DIM-807/00 /4...
  • Page 6 WARNING THE WORKING PRESSURE. IF THE FUNCTION IS NOT USED: • LOW COOLING IT IS NOT NECESSARY TO LIQUID LEVEL ADJUST THE PRESSURE CONNECT CONNECT TER- MIINAL33 TO EARTH SWITCH AGAIN IF THE WORKING PRESSURE REMAINS UNCHANGED. GB DIM-807/00 /4...
  • Page 7 For ELECTROMAGNET stopping, STOP connect terminals 39 and 40. EXCITATION ELECTROMAGNET for pulling STOP lever 39 40 COOLING LIQUID LEVEL PROBE FOR RADIATORS WITH FOR RADIATORS WITH PLASTIC EXPANSION TANKS METAL EXPANSION TANKS SCREW ELECTRODE ELECTRODES GB DIM-807/00 /4...
  • Page 8: Device Test

    FUNCTIONS BUT THE ENGINE DOES NOT - Fuel supply circuit defect - Check that the stop system (solenoid or START electromagnet) functions - Consult the engine instruction manual - Low temperature - Check that the preheating functions GB DIM-807/00 /4...
  • Page 9: Troubleshooting

    - Check that during the stop phase there is - Defective device voltage on terminal (5) (see STOP on page 4), simulate the function (see DEVICE TEST on page 8 and if necessary replace the device (*) GB DIM-807/00 /4...
  • Page 10 Our assistance service is always at your disposal. When you contact us, you should be ready to provide the following information: - The type of equipment installed - The problem encountered - The state of the dashboard indicators when the problem arose - Any previous corrective action taken GB DIM-807/00 /4...
  • Page 11 19.01.15 FOR OHTER ACCESSORIES AVAILABLE ON REQUEST SEE PAGE 7 ACCESSORIES DATA FOR ORDERING MOBILE SOCKETS ENGINE PROTECTIONS DEVICE type PMO-134/00 code 80.42.34 type DIM-807/00 12 V code 03.02.03 type PMO-136/00 code 80.42.36 type DIM-807/00 24 V code 03.02.04...
  • Page 12: Technical Data

    IP 65 / IP 00 WEIGHT 460 g CONFORMITY DECLARATION The company Elcos s.r.l. assumes full responsibility for declaring that the equipment: DIM-807/00 type: when used in the ways and for the purposes described in the enclosed documents is in conformity with the following directive:...