REMEMBER: the AG system is to be used ONLY with an RC-11 or RC-35/22 cell. Use of any other cell
may cause equipment damage and void warranty.
The SuperCell may require removal for periodic visual inspections, or for servicing when debris or
calcium mineral deposits develop. The need to inspect and service the cell may be indicated by the
"Check System" light flashing red and the message, "Lo Flo", P = OFF, or A = "Lo".
Removal of the SuperCell...
The SuperCell is installed with Unions on each end to allow quick and easy installation and removal.
1. Turn off pump and shut off all power.
2. Detach the SuperCell cable from the
SuperCell.
3. Unscrew the unions at both ends of
the SuperCell.
4. Slide the SuperCell out of the Manifold
Assembly.
Visual Inspection of the SuperCell...
Remove the SuperCell from the Manifold Assembly,
following the directions in the previous section. The
SuperCell titanium blades, seen inside the cell body,
should be straight and clear of any debris on the ends
or between the blades.
A white flaky or crusty calcium build up on the
edge or between the blades will shorten the
life of the cell.
Clean the cell immediately, and determine the cause
of scaling. See "Basic Water Chemistry," and "Using
the Saturation Index" ... on pages 18-19 for salt, and
pages 21-22 for E4aqua . Also see "Manual Cleaning
of the SuperCell" ... on next page.
Your AG is designed to automatically self-clean calcium scale build up that may form on the blades during
normal operation. However, unbalanced water chemistry can cause a heavy scale build up exceeding
self-cleaning capabilities... thus; periodic manual cleaning may be necessary. The simplest way to avoid
this extra work is to maintain the water chemistry at the levels recommended.
CAUTION !
For maximum cell life, maintain water in a balanced condition. Water maintained in a scaling con-
dition will shorten cell life and may render the chlorinator inoperative. Damage and/or service
calls, caused by improper water balance, will NOT be covered under the equipment warranty.
24
MAINTENANCE
Servicing the SuperCell
Failure to heed the following may result in equipment
damage.