Electrical Connections:
All electrical connections should be made by a licensed electrician or certified electrical contractor.
The AG 75090 and 75090-TL have been configured for 115-VAC operation. The AG 75091 has been factory
configured for 230-VAC operation. The configuration can be changed in the field.
The reconfiguration from 110 to 230-VAC requires removal of the power cord, and changing jumpers inside
the unit. Also, the fuse has to be changed: 1-amp slow blow for 230-VAC (110-VAC units use a 2-amp
slow blow fuse).
The control center uses both high (line) and low voltage connections. Line-voltage connections are intended
as electrical input to the power center. Low-voltage cables connect to the Flow-Switch and SuperCell.
WARNING !
RISK OF ELECTRICAL SHOCK... Insure electrical power is disconnected before wiring the unit.
Follow all state / local / NEC (CEC if applicable) electrical codes. Use copper conductors, only.
Grounding and Bonding:
The AG must also be connected to the pool/spa bonding system with an 8-AWG (6-AWG for Canada)
wire. A bonding lug is provided at the bottom, exterior of the control center.
High Voltage Wiring:
Determine what type of connector is to be used when installed the AG power supply. (Three-Prong connector,
Twist-Lock connector, or hard wired to the electrical panel) then connect as show on diagram below.
12
INSTALLATION
Failure to heed the following may result in permanent
injury or death.
Three-Prong Connector:
Twist-Lock Connector: