Plumbing the Floating-Cell Manifold Assembly (75092):
STEP-1: Select the area where you would like the swan to float:
Confirm floating cell's cable will still reach power center as swan floats in pool. The cell cable
is 25' long.
Make sure that cord will not become a tripping hazard when in pool.
STEP-2: Assemble swan as shown:
1
Unscrew the GRATE from the bottom of the RC-11 Cell
(The grate is included with the cell as Part # RC-11-ML-CC25)
2
Unscrew the CANISTER from the SWAN
(The Cannister is included with the Swan as Part #19088)
3
Insert the RC-11 CELL into the CANISTER, lining up the cable with
the notch on the side of the CANISTER and the hole in the bottom
4
Line the GRATE up on the outside of the CANISTER and screw it
into the RC-11 cell
5
Screw the SWAN assembly into the top of the CANISTER
6
Place SWAN assembly into pool
7
Attach cable to AG Control Unit
8
Plug in AG and enjoy!
Plumbing the Above Ground Manifold Assembly (75093):
STEP-1: Select the location for installing the manifold:
It is recommended the manifold be installed prior to installation of the Control Unit. The Control
Unit must be installed close enough to the Manifold Assembly to allow the SuperCell suf-
ficient slack to enable component service and maintenance. The cables are 12' long.
The direction of the water flow through the manifold must be as indicated for the system to
operate properly.
STEP-2: Lower the water level below the return line.
STEP-3: Install the 75093 into the return line hole and tighten the nut inside the pool wall.
STEP-4: Connect the return pipe to the bottom of the cell.
2" PVC (312-D) or
• 1 1/2" flexible hose or 1 1/4" flexible hose (312-G)
STEP-5: Add water to bring the level above the return line.
Plumbing the Inline-Cell Manifold Assembly (75094):
The Manifold Assembly is typically plumbed into the pool return line; and, if applicable, after the heater
and spa return diverter valve.
STEP-1: Select the location for installing the manifold:
It is recommended the manifold be installed prior to installation of the Control Unit. The Control
Unit must be installed close enough to the Manifold Assembly to allow the SuperCell and
flow switch cables sufficient slack to enable component service and maintenance. The cables
are 12' long.
The direction of the water flow through the manifold must be as indicated for the system to
operate properly.
For a Pool/Spa combination, the manifold must be located as the last component in the POOL
RETURN LINE (to avoid over-sanitization of the spa).
10
INSTALLATION
Adaptors are supplied for 2" PVC (312-D) or 1 1/2" flex hose (312-G).
Adaptors are supplied for:
Swan
Cannister
Grate