Qsi (Input Signal Data); Drv (Panel Drive-Power On / Off) - Pioneer PDP-4280HD Service Manual

Plasma display system
Hide thumbs Also See for PDP-4280HD:
Table of Contents

Advertisement

1

9.3.12 QSI (INPUT SIGNAL DATA)

The command QSI is for acquiring all data on input video signals.
A
Command
Effective Operation
Format
[QSI]
All operations
Data Arrangement
ECO
1
Type of drive sequence
2
Standard/nonstandard
B
3
Type of ABL/WB tables
4
Total value of PCN
5
Total value of PRH
6
Total value of PGH
7
Total value of PBH
8
Total value of PBR
9
Total value of PRL
10
Total value of PGL
11
Total value of PBL
C
12
Total value of ABL
13
Detection of V frequency
14
Reserved
15
Reserved
16
Obtained APL data
17
Number of SUS pulses
18
Result of detection of still picture
19
Result of detection of cracking in the panel
20
Result of detection for scanning protection
21
Result of detection for external protection
D
22
Transition of protection operation
23
Reserved
CS

9.3.13 DRV (PANEL DRIVE-POWER ON / OFF)

Drive ON/OFF: ON/OFF control of panel drive-power system
E
Command
Effective Operation
Format
[DRV+S00]
Every time
[DRV+S01]
Every time
Once the DRIVE OFF command is accepted, DRIVE OFF cannot be canceled by pressing the DRIVE OFF key again or by
turning the unit off then back on with the STANDBY OFF/ON key.
To cancel DRIVE OFF, restart the unit by unplugging then again plugging in the power cord.
F
156
1
2
Modes
To acquire all data on input video signals
Data
Length Output Example
3 Byte
3 Byte
1 Byte
2 Byte
4 Byte
4 Byte
4 Byte
4 Byte
4 Byte
4 Byte
4 Byte
4 Byte
3 Byte
4 Byte
1 Byte
3 Byte
4 Byte
4 Byte
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
4 Byte
2 Byte
Modes
DRIVE OFF
DRIVE ON (default)
2
3
Function
Return data: 3 (ECO) + 66 (DATA) + 2 (CS) = 71 Byte
QSI
60V
S
T1
0256
0256
0256
0256
0512
0512
0512
0512
128
6002
∗∗∗
1023
0457
1
1
1
1
0
∗∗∗∗
27
Function
PDP-4280HD
3
4
Remarks