B e f o r e Y o u B e g i n P l e a s e r e a d t h e i n f o r m a t i o n c o n t a i n e d i n t h i s m a n u a l c a r e f u l l y b e f o r e p r o c e e d i n g w i t h t h e i n s t a l l .
C o n d i t i o n s f o r U s e CAUTION DO NOT USE WITH WATER THAT IS MICROBIOLOGICALLY UNSAFE OR OF UNKNOWN QUALITY WITHOUT ADEQUATE DISINFECTION BEFORE OR AFTER THE SYSTEM THIS DRINKING WATER SYSTEM IS FOR USE ON POTABLE COLD WATER SUPPLIES ONLY Source Water Supply Municipal/Private: Potable Water Supply...
- Optional drip tray to drain connection The Ascent™ 80 is available in two filter configurations: 1. Ascent 80-RO: This Ascent 80 R model filters your water through a series of filters and an RO membrane to reduce contaminants. These are: A 10 micron sediment filter (P/N BFC-SED)
R e c e i v i n g Yo u r E q u i p m e n t A common carrier will be delivering your Culligan Ascent 80 product. Upon receipt you should check the following. Are the systems still on the pallet? Count the number of boxes you are signing for.
S a f e t y P r e c a u t i o n s Warning: Do not install or use this drinking water system where the source water is microbio- logically unsafe or with water of unknown quality without adequate disinfection before or after the system.
Page 7
•To prevent electric shock and fire hazards, do not use with other than specified power source. •Changes or modifications not approved by CULLIGAN WATER will void any product warranty. •If system begins to leak, unplug, turn o water supply and call service center immediately.
4.The Ascent 80 system requires a waste or drain line for the RO membrane. The drain line should include an Air Gap and back flow restrictor. See diagram.
F i l t e r F l u s h i n g P r o c e d u r e s - R O V e r s i o n Filter Flushing Procedures for Ascent 80-RO Filter Configuration The filters can be flushed either outside of the BFC (External) or within the BFC (Internal).
Page 10
F i l t e r F l u s h i n g P r o c e d u r e s - R O V e r s i o n Reverse flush the post carbon filter. a.
Page 11
F l u s h i n g P r o c e d u r e s - M i c r o - F i l t r a t i o n V e r s i o n Micro Filtration - External Flushing 1.
S a n i t i z a t i o n I n s t r u c t i o n s Sanitizing the Cold Tank: It is strongly encouraged that all systems are sanitized using a mixture of Hydrogen Peroxide and water prior to placing in the field.
F i n a l I n s p e c t i o n Verify the following: There are no leaks or loose components. The hot water is over 160°F. The cold water is below 50°F. Confirm acceptable product water flow The system exterior is clean and all components are in place.
S y s t e m P r o g r a m i n g I n s t r u c t i o n s Circuit board schematics and Dip Switch Settings This system allows for the dealer to adjust the following by using dip switches: 1.
Page 16
Service indicator, Flow Rate, and audible Beep tone. NOTE: The Ascent 80 makes a beep noise when a sensor is triggered. For programming, there is a second noise, which we call a Chime. The Chime is an ascending tone of 3 to 6 notes. Do not assume the beep is the Chime.
Page 17
S y s t e m P r o g r a m i n g I n s t r u c t i o n s Flow Rate: The dispense Flow Rate on the Ascent 80 is set to 3 liters per minute. This is twice as fast as a traditional cooler and is ideal for filling larger bottles.
P r e v e n t a t i v e M a i n t e n a n c e 1. Change filters according to the filter change schedule. 2.Reset the filter alert using the instructions above. 3.Descale the hot tank.
The below diagram shows the functions of the interface of the Ascent 80. • The Ascent 80 uses touchless sensors to detect an object in front of the sensor. The sensor can be used either as touchless or with touch.
The Culligan Ascent 80 system is certified by IAPMO R&T against NSF/ANSI/CAN 61: Q ≤ 1, NSF-372 and CSA B483.1 for material safety, structural integrity, and lead free requirements.
Dealer/Dis-tributor. Additional Warranty through Fifth year: CULLIGAN promises that after the end of the initial warranty through the fifth anniversary of the initial limited warranty to supply a new compressor if proven defective by a qualified CULLIGAN approved technician.
Export Warranty: The CULLIGAN export warranty shall apply to all area outside of the Continental limits of the United States and Canada. The export warranty shall mirror the domestic warranty set forth above in all respects except that a) the export warranty shall be limited to the Initial Term and there is no coverage for the additional warranty through the fifth year and b) the Dealer/Distributor shall be responsible for any and all transporta-...
Need help?
Do you have a question about the Ascent 80 and is the answer not in the manual?
Questions and answers