Technical Data; Electrical Connection - Zanussi ZBF 863 Instruction Booklet

Zanussi instruction booklet built-in oven zbf 863
Table of Contents

Advertisement

Installation
The oven must be installed according to the
instructions supplied.

Technical Data

DIMENSIONS
Height
OF RECESS
Width
Depth
DIMENSIONS
Height
OF THE
Width
OVEN CAVITY
Depth
Oven capacity

Electrical Connection

The oven is designed to be connected to 230-240V
(50Hz) electricity supply.
The oven has an easily accessible terminal block
which is marked as follows:
Letter L
-
Live terminal
Letter N
-
Neutral terminal
or E
-
Earth terminal
THIS OVEN MUST BE EARTHED
The cable used to connect the oven to the electrical
supply must comply to the specifications given
below.
For Uk use only
Connection
Min. size
via
Cable/flex
• 13 A socket 2.5 mm
outlet
• 13 A
spur box
• Cooker
2.5 mm
Control
Circuit
For Europe use only
Min. size Cable/flex
2
1.5 mm
22
580 mm.
560-570 mm.
550 mm.
320 mm.
420 mm.
390 mm.
53.2 litres
Cable / flex Fuse
type
2
3 core
13 A
butyl
min.
insulated
2
PVC/PVC
15 A min.
twin and
20 A max.
earth
Cable / flex type
Fuse
H05 RR-F
13 A
This oven must be installed by qualified
personnel to the relevant British Standards.
Heating element ratings
Oven element
Grill element
Oven Light
Cooling Fan
Convection Fan
Total Rating
It is necessary that you install a double pole switch
between the oven and the electricity supply (mains),
with a minimum gap of 3mm between the switch
contacts and of a type suitable for the required load in
compliance with the current rules.
The switch must not break the yellow and green earth
cable at any point.
Important
After installation and connecting, the cable must be
placed so that it cannot at any point reach a tempera-
ture of more than 60 C above the ambient temperature.
Before the oven is connected, check that the main
fuse and the domestic installation can support the
load; and that the power supply is properly earthed.
The manufacturer disclaims any responsibility
should these safety measures not be carried out.
2.08 kW
1.82 kW
15 W
25 W
30 W
2.15 kW