Taxa Outdoors Mantis 2021 Owner's Manual page 62

Table of Contents

Advertisement

Low water pressure
Fresh tank won't fill
Water pump not working
Water heater not working
Electrical
Description
120v circuit breaker pops
Battery not charging
(see LED volt monitor:
– a well charged battery is
between 12.6 and 12.8V
M A N TI S www.taxaoutdoors.com
1830 west 15th street houston, tx 77008 usa
is being regulated by pressure
regulator at inlet.
Tighten line by checking
connections back to water tank
from sink; tighten or re-connect.
Check connection also beneath
habitat. Sometimes you can
Drawing air in water
hear air entering line when water
supply line
pump is turned on.
Hose improperly
inserted
Use fill line connector
Blow out vent line (small hole
just above fill area)
If crimped, remove bend in line.
Vent blocked up or
(accessible by removing service
crimped
panel beneath Vberth)
Check fuse beneath
water pump switch at
kitchen.
Replace pump
Verify that furnace (heat) is
working. Check LCD control
panel to make sure setting is
correct, not on a timer that timed
out. Check top of furnace unit
itself to verify that small switch is
in ON position. Note that water
heating speed depends on inlet
no hot water
temp.
no power (no LEDs
Check fuse on switch plate at
on unit)
kitchen.
Check GFCI breaker where
heater plugs into outlet beneath
cabinet. Reset.
check TRUMA manual
if propane
troubleshooting
check propane supply and
if propane
valves
Possible cause
Fix
Wet extension cord
Dry cord, reset breaker.
Check tow hitch connection and
wiring. Verify that interior volt
7-pin connection
meter jumps up in voltage when
short
car is turned on and 7 pin is in
(rev.08262020)