EN
40 | WECOUNT
WECOUNT technical data
(Electronic register)
IP protection class
Radio standard
Radio frequency
Radio range/ transmission
power
Battery
Interface
Storage temperatu-
re
Ambient temperature
Translations
For delivery to countries of the European Economic Area, the
operating instructions must be translated into the language of
the country of use� Should discrepancies occur in the
translated text, either consult the original operating
instructions (German) for clarification or contact the
manufacturer�
IP68, (4 weeks, max. 1 meter under water)
EN13757-4, wMBus according to OMS
(Open Metering System), T1, C1 mode,
AES-128 Encryption (4
Mode 5, Security Profile A)
868�95 MHZ
1�5 kilometres in open space / 14 dBm
1 lithium cell, 3.6 V
Size ½ AA, lifetime up to 7 years (optional)
Size 1 AA, lifetime 13 years to 16 years
NFC; 13.56 MHz; 4800 baud
+0.1 °C to +65 °C, dry
+0.1 °C to +65 °C