IF YOUR FREEZER DOES NOT FUNCTION SATISFACTORILY
Check the following before calling for service staff:
Defect:
Check if:
Freezer not
Green light not on
cold enough
Green and red light on
Green light on, red
light not on
Yellow light on
Freezer too
cold
Yellow light not on
Too much
Lid does not close
frost
completely
formed
Lot of moisture in the
room
Goods packed poorly
The pressure equalisa-
tion valve does not
close appropriately.

HOW TO CHANGE THE BULB

Before changing the bulb, isolate the appliance from the electricity supply. Unscrew the bulb, and
replace it with a new bulb (max. 15W). Then reconnect the electricity supply. Extra bulbs are available
from your local Zanussi Service Force Centre.
ACCESSORIES
Spare baskets can be obtained from your local Service Centre. The illustra-
tions on this page show how many baskets can be placed in the various freez-
er models.Measure the length of your freezer and find the appropriate illustra-
tion. The number above each illustration indicates its length in millimetres.
ZANUSSI STANDARD GUARANTEE CONDITIONS
This guarantee is in addition to your statutory and other legal rights which will not be excluded or in any way diminished by
the return of this guarantee card.We, Zanussi Ltd., undertake that if within twelve months of the date of the purchase, this
ZANUSSI appliance or any part thereof is proved to be defective by reason only of faulty workmanship or materials, the
company will, at its option repair or replace the same FREE OF ANY CHARGE for labour, materials or carriage on condi-
tion that: The appliance has been correctly installed and used only on the electricity supply stated on the rating plate. The
appliance has been used for normal domestic purposes only, and in accordance with the munufacturer's operating and
maintenance instructions. The appliance has not been serviced, maintained, repaired, taken apart or tampered with by
any person not authorised by us. The appliance is still in the possession of the original purchaser. All service work under
this guarantee must be undertaken by a Zanussi Service Force Centre. Home visits are made between 8.30am and 5.30pm Monday to Friday. Visits may
be available outside these hours in which case a premium will be charged. Any appliance or defective part replaced shall become the property of this com-
pany.
EXCLUSIONS
This guarantee does not cover: Damage or calls resulting from transportation, improper use or neglect, the replacement of any light
bulbs or removable parts of glass or plastic. Costs incurred for calls to put right machines improperly installed or calls to machines out-
side the United Kingdom. Appliances found to be in use within a commercial environment, plus those which are the subject of rental
agreements. Products of Zanussi manufacture which are NOT marketed by Zanussi Ltd. EEC Countries - the standard guarantee is
applicable but is subject to the owner's responsibility and cost to ensure the appliance meets the standards set by the country to which
the product is taken. The Zanussi Company in the contry co cerned will be pleased to advise further. Sight of your purchase receipt
will be required by them.
18
Possible cause:
Plug not connected correctly
Defect in switch or fuse
Power failure
Fresh food recently placed in freezer
Lid open too long
Thermostat set too warm
Lot of frost and ice formed
"Super" function active
Thermostat set too cold
Lid in contact with goods in free-
zer
Moisture from washing machine,
tumble-dryer, etc.
Lot of moisture from goods
Some pollution has got into the
valve.
Action:
Check plug and socket
Check fuse, call electrician
Wait until current returns
Wait a couple of hours
Wait a couple of hours
Set thermostat colder
Defrost freezer
Press "Super" button out
Set thermostat warmer
Re-arrange goods, check that lid
closes correctly
Move freezer to a room with less
moisture, or air regularly
Re-pack goods, see under
"How to use"
The valve must be blown through
from the airing outlet in the rear wall.