Sargent & Greenleaf 6120 – To open the Lock
1. Press the code digits or letters in order, followed by #. (The lock is shipped
from the factory with a factory master code only. It is 1 2 3 4 5 6 #.) The lock
bolt will retract for six seconds, allowing you time to operate the safe handle
and open the door. Do not put any pressure on the safe handle until after the
6 digit code has been entered. The Model 6120 will lock automatically when
the safe door is closed and the handle is turned to the locked position.

Changing the Master Code

1. Press 74.
2. Press *.
3. Enter the existing six-digit Master Code.
4. Press #1*.
5. Enter the new six-digit Master Code.
6. Press #.
7. Enter the new six-digit Master Code again.
8. Press #. The lock will emit 3 distinct chirps if the new code is accepted. If a
long tone is heard the code is not accepted.

Changing/Adding a User Code

1. Press 74.
2. Press *.
3. Enter the six-digit Master Code.
4. Press #.
5. Enter the user number (2 through 9).
6. Press *.
7. Enter the new six-digit user code.
8. Press #.
9. Enter the new six-digit user code again.
10. Press #. The lock will emit 3 distinct chirps if the new code is accepted. If
a long tone is heard the code is not accepted.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 6120 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sargent and Greenleaf 6120

  • Page 1 Do not put any pressure on the safe handle until after the 6 digit code has been entered. The Model 6120 will lock automatically when the safe door is closed and the handle is turned to the locked position.
  • Page 2 5. Enter the user number (2 through 9). 6. Press *##. The lock will emit 3 distinct chirps to indicate the user is deleted. S&G 6120 Lock Won’t Open 1. Replace the batteries. Make sure to use good quality alkaline batteries: Energizer (first choice) or Duracell (second choice).

Table of Contents