Fault Codes

The battery condition meter will flash fault codes when the controller system detects an abnormal
condition in the electrical system. All of the battery condition meter LEDs will flash a number of times
quickly, then pause, then flash again. The battery condition meter will continue to flash the fault codes
until the problem is fixed. The table below identifies the individual fault codes. If any of these fault codes
persist, contact your authorized Pride Provider.
Fault Codes
1 Flash
2 Flashes
3 Flashes
4 Flashes
5 Flashes
Scroll Left
to Right
7 Flashes
8 Flashes
9 Flashes
10 Flashes
Left red LED
flashes 4 times
in 0.5-second
intervals at power
down.

Care and Maintenance

Refer to your power chair owner's manual for proper cleaning and disposal instructions.

Warranty

Refer to your power chair owner's manual for specific information on controller warranty.
Probable Causes
The batteries need charging.
There is a bad connection to the
batteries.
There is a bad connection on the left
motor.
The left motor has a short to the
battery connection.
There is a bad connection on the
right motor.
The right motor has a short to a
battery connection.
The
charge
inhibit
activated.
There is a joystick fault.
There is a control system fault.
The park brakes have a bad
connection.
An excessive voltage has been
applied to the control system.
Power chair has been driven for 8
hours or more and the batteries have
not been charged.
Check the battery connections. If the
battery connections are good, then try
charging the batteries.
Check the left motor connections and
wiring harnesses.
Contact your authorized Pride Provider.
Check the right motor connections and
wiring harnesses.
Contact your authorized Pride Provider.
has
been
Make sure that the battery charger is not
connected to the power base.
Make sure the joystick is in the center
position and then power off and on again.
Check power module and joystick module
connections and wiring.
Ensure that both freewheel levers are in
drive mode. Check the left and right motor
connections and wiring.
Check the battery connections.
Fully charge the batteries for 8 to 14 hours.
The controller must be powered on during
charge cycle.
Possible Solutions