4.2.13 Status information
Description
Interface
System information:Power-up mode, standby
mode, hybrid grid-connection, off-grid operation,
STATE
mains charging mode, PV charging mode, bypass
mode, fault mode, DSP programming, ARM
SYS:
ERROR
programming.
INV:
STANDBY
INV: standby mode, off-grid inverter mode, grid-
DCDC:
STANDBY
connected mode, and transition of grid-connection
to off-grid, transition of off-grid to grid mode.
DCDC: standby mode, soft start mode, charging mode.
4.2.14 Error information
Interface
Interface
ERROR NO.
WARNING:
W11-1
FAULT:
F10-1
4.2.15 System setting
Description
Interface
Status mode: Self-generation and self-
consumption,Peak load shifting,and Battery
priority.
SYSTEM
Grid-connection standards: China, Germany,
STATE: PEAKS HIFT
Australia, Italy, Spain, UK, Hungary, Belgium,
GRID STD:
China
Western Australia, Greece, France, Bangkok,
PV I/P:
INDEPN
Thailand, local and 60HZ.
PV input mode:independent connection, parallel
connection,constant voltage.
Press ESC button to enter user setting
4.2.16 User setting
37
www.kstar.com
User Manual
Alarm code (see Chapter 9)
Error code (see Chapter 9)
User Manual
Description
Interface
-USER-
Press ESC on the Main Display Interface to enter
→1 :SETUP
the user interface.
2:INQUIRE
See chapter 8.2 for more setting details.
3:STATISTIC
Enter the password before setting up the user.
Interface
Description
After entering the setup interface, the system will
prompt to input password;
The default password is"000000", which can be
altered in Password setting menu;
-PASSWORD-
Press UP/DOWN button to increase or decrease
INPUT:
XXXXX
the figure that is input;
Press ENTER button to move the cursor
backwards or confirm the setting;
Press ESC button to move the cursor forward.

4.3 Setting

Description
Interface
--S ETUP--
→1:SYS SETTING
This interface is used for various information
2:BAT SETTING
inquiry options.
3:GRID STD
Press UP/DOWN button to move the corresponding
4:RUN SETTING
options.
Press ENTER to enter the selected menu.
5:485 ADDRESS
Press ESC button to return to the user interface.
6:BAUD RATE
There are 13 options in total, including system
7:LANGUAGE
mode, battery parameters, grid standard, operation
parameters, 485 address, 485 baud rate, language
8:BACKLIGHT
display, LCD backlight, date/time, clear history,
9:DATE/TIME
password setting and maintenance, and factory
10:CLEAR REC
setting.
11:PASSWORD
12:MAINTENANCE
13:FCTRY RESET
14:AUTO TEST