IP Power 9820 MT User Manual Version: V1.00 ( Firmware Version: 1.19_565 ) Date Released: JAN. 2020 - 1 -...
Page 2
Warning: Any changes made to this equipment without permission may cause damages to the device! IMPORTANT NOTICE 1. IP Power 9820 MT was designed for indoor use, we carry no responsibility for possible damages caused by outdoor use, especially in the rain.
1. Introduction IP Power 9820 MT is a new generation of the Power Distribution Unit (PDU) & Remote Power Control (RPC) system. Its able to control in the network With embedded web server and HTTPS protection , 9820 MT supports higher grade security as working on Internet.
16. Protection of “ FUSE ” & " Inrush Current - Power Surge " - fit for Light control application 17. App “IP Power “ – free download in Google play or App Store - Controls the outlet power ON/OFF without doing Port Forwarding / Port Mapping - Quick search in LAN / WAN ( like IPEDIT &...
20. Specific software developed by Aviosys and provided free of charge : - SDK Available : HTTP Command ( Compatible with 9820 ) - IP Power Center - control multiple Aviosys IP devices in same AP. - CNT software ( Cross Network Technology )- allows user eliminate set up work on any Router without port forwarding- No Need to do Port Forwarding .
2.3 Minimum System Requirements Web Browser of WINDOWS / iOS / Android : Google Chrome , Safari , IE and so on . Network connection for Internet connection . Internet HUB & Switch ( with RJ45 port) 2.4 Package Contents 9820 , IR remote power controller , EARs ( with screws) , DI connector and Cable Tie .
reset button with a sharpen pin for 10 seconds then release. There are THREE beeps response ( short –- mid long – short ) which means reset successfully and 9820MT will be rebooted itself ( one beep after reboot ) and most information go back to default setting .
The Maximum current of each outlet is 10A / 240VAC . 9820MT-T : NEMA 5-15 . The Maximum current of each outlet is 15A / 100VAC 3. Setting up your device 3.1 Before Starting *Before setting up the device make sure of the following: All the package contents are all included if anything is missing please contact the dealer where the device was purchased from.
. The note with this online CD link comes with the package . IP Power Software: IP Edit ( Required) IP Power Center *( For multiple IP Power devices control purpose ) 1.) Select the IP Power 9820 MT - 11 -...
“ IPEDIT “ 3.3.1 LAN connect by IP Search software IP Edit is a search tool designed to search, configure, or access the IP Power 9820 MT from a local networked computer. IP Power 9820 MT Default Login / Password Default IP: 192.168.1.168 ( if there is...
Page 13
Notice : If can’t see the IP in the area of Local Devices of IPEDIT.exe. Please check the following situation 1. Boot up successfully : Please reboot the 9820 MT and check if there are 1 short beep after 1 minutes . This beep means the device boot up successfully . If not , the device may have issue.
Page 14
Check to see that the gateway IP and the IP Address (9820 MT) match user current network. If not, type in the correct information, then hit the submit button to save changes. For example: If user have the following information regarding the 9820 MT and user network User PC Network : Computer IP Address: 192.168.1.122 Gateway: 192.168.1.1...
Setup Port Mapping / Port Forwarding in your router. Please check your Router owner’s manual . ⚫ Use our own software “ IP Power Center “ : Please refer to the “IP Power Center “ manual in software section of www.aviosys.com/cd 3.3.3 Using IP Service...
Page 16
1.) Open IP Edit and select the server that user’s 9820 MT is designated to. 2.) Hit the Green Connect button on the top of IP Edit. 3.) Then type in the 9820 MT Name that user have selected for the device and press the Search button.
Password: 12345678 The Control Console The Right side Menu of the Web Interface control the functionality and setup of the IP Power 9820 MT. The IP Power 9820 MT Console consists of six main sections which will be explained in details below.
This section show the device name . You can change the device name here : Application → IP Service → Device name Change name “ IP POWER 9820 MT “ as “Enjoy 9820 MT “ Notice : Please do not use symbol like !@#$%^&*()_+ as the character of the device name .
Without left control section : 4.1.3 Time : In this section, it shows Time at Year – Month – Date Hours : Minutes : Seconds . To setup the Time , Please go to “ System → Management → NTP Settings “ , please press “Apply”...
2. Current time - sync with the local PC log into 9820 MT . 3. NTP Server - sync with the assigned sever and can setup the times for sync Notice : As using NTP server , as webpage time count will be slower than the device time , please refresh the webpage or use the TELNET command “...
Page 21
A. Power Control : User can do the following 3 basic operation in this page : 1. Manually Control : Each port ON or OFF directly by pressing the button. For example : The following pictures means that Power #1 & #4 is ON , Power #2 & #3 is OFF Power Cycle : Manually Control the relay delay some times to turn ON or OFF .
Page 22
User can setup the time and the final status in power cycle as ON / OFF For example : ( sec = seconds ) Original Outlet as “ ON “ , select final status as “ OFF “ & fill 3 sec . After press “ power cycle “ button, the outlet will be ON for 3 seconds and then turn OFF .
Page 23
Original Outlet as “ ON “ , select final status as “ ON “ & fill 10sec . After press “ power cycle “ button, the outlet will turn OFF for 10 seconds and then turn ON . ON -- > OFF ( 10 sec ) → ON Group Setting : User can control more than one outlet by press the right side “Apply “...
Page 24
Name of each port User can name each power by click the name above the power button . The number of character is max. 12 characters and Please change the name in English only and do not use symbol like !@#$%^&*()_+ Note : Please change the name in English only and do not use symbol like !@#$%^&*()_+ Example : Change the outlet #1 from “...
Page 25
B.2 Notification setting User can do several notification here . ⚫ Forbidden off manually : Select by port will disable the power control in webpage . The disable is for the control in webpage only .The control through HTTP command is still working .
Page 26
⚫ Forbidden power cycle : Select by port will disable the power cycle control in webpage . The disable is for the control in webpage only .The control through HTTP command is still working . For Example : Select the power cycle control in webpage of power 1 & power 2 for be disable ⚫...
Page 27
⚫ Beep Alarm Setting: User can setup the operation beep ( short time beep) sound here. ⚫ Current Alarm Setting: to enable the protection as over current and setup the maximum value. The range of each outlet is 1~ 10 amp . As over the setting value, 9820 will keep beeping for several times and then turn OFF the power output automatically.
Page 28
9820 MT can be used to safely turn off the WINDOWS or LINUX system through Network. With this feature you can remotely shutdown any system which that is connected to the IP Power 9820 MT through normal Windows / LINUX shut down procedure. Before operating the software shutdown function it is essential to install our software.
Page 29
⚫ LCD Display : User can select the display contents in LCD panel : Show either fix contents - “ T/V/IP = Temperature / Volt / IP “ or “ IP “ “ Current of outlet #1~ #4” or “ Current of outlet #5~ #8 “...
4.2.2 Schedule In this section , user can see the setting schedule list first up to 29 rules . To setup each schedule , please press “ Schedule Setting “ , then user can get the “ Schedule List “ page as following : Please click the button to switch between “...
Page 31
Adding a Scheduled Event 1. Select the Action Duration : There are 3 setting - Once , Every Day . Every Week 2. Select a Specific Date Range where the device will repeat the desired actions during the time specified. 3.
Apply / Edit a Schedule Event : Please select the Rule you want to edit in Scheduler Table. , Change the setting like Duration , Date , Time and Action. Then Press “Apply Np. X Sch “ button to confirm the setting and you will see the page refresh and new setting display in Scheduler list Delete - Click “...
Page 33
Ping Setting Page : There are 3 sections of the setting area : 1. Setting Rule Numbers : User can click to select different rules numbers at the right side button “ Rule No: X “ as following pictures . There are 29 rules available. 2.
Page 34
As setting finished , please click “ Apply “ to save the setting in this area , the webpage will refresh and user can see the final setting result. Ten different set up rules for different port . 3. Other Setting : The setting here is for each rule .
Page 35
( ex: www.google.com) user would like to Ping. User can use the “ ping test “ bottom to check the address valid or not ⚫ Failed times then action : Setup the ping failure times for 9820 MT to execute the setup ON/OFF / Reset action of setting .
4.3 Network : There are 3 sections in this port : LAN Network , DNS setting and Port setting LAN Network Settings : The network status is connected by ether cable with RJ45 connector . There are 3 network connection way : Static IP / DHCP / UPNP A.
Page 37
User can only revise the Host Name under DHCP mode. This is also the default setting for fast LAN connection solution. As the IP from DHCP Service of user`s router will be changed by router . 9820 MT will remember last IP of 9820 MT assigned by user`s router in “Last DHCP state “...
4.4 Application Settings : 4.4.1 Email There are 2 sections in this part -- E-mail setting and POP3 Control : ⚫ Email Setting : User can get e-mail advice as one of the following situation happen : Receive E-mail with IP information & MAC Address as 9820 MT device boot up. Receive E-mail as ON/OFF status change in each output .
Page 39
The 9820 MT allows user to send from public e-mail account , such as @gmail or @hotmail or @yahoo.com ⚫ SMTP Server: This is the mail server of sender . If user select @gmail or @hotmail account as SMTP Server , 9820 MT will fill the SSL & Port automatically ⚫...
Step 3 : If message show “Fail “ , please turn ON the setting in your gmail account - Turn ON Less secure app access “ the function ⚫ Procedure : Go to your google account → Security → Turn ON the function “ Less Secure appsaccess “...
Page 41
Notice : You will not see the section “ Less secure app access “ if your gmail account turn ON the function “ 2-Step Verification “ . Please turn it off as following picture or use another gmail account . ⚫...
Page 42
Settings Section : To set up 9820 MT be controlled by e-mail , user need to know the both sender`s e-mail address and receiver`s e-mail account Name and Password. ⚫ POP3 Server: This is receiver’s mail server ⚫ From : Sender’s email address . Ex.: aviosys@gmail.com ⚫...
Page 43
⚫ CTRL format : Control format by subject or by body ( e-mail contents) For example : Use Gmail as sender and receiver Sender`s e-mail : 123@gmail.com Username to log in sender`s @gmail : 123@gmail.com abc@def.com Password to log in sender`s @gmail : 12345678 Command format &...
Page 44
There are 2 section of the command IPPOWERCTRL:TAG=Test This is command part. Beside the tag message part ( like Test on above example) user can change in setting section , the other command must be CAPITAL and are fixed content . 2.
4.4.2 DDNS The DDNS section allows user to setup the 9820 MT with a DDNS server (i.e. www.dyndns.com). After the server has been setup correctly, enter the necessary information into the 9820 MT DDNS settings. Note : The DNS server will have extra change as apply new account. Account : the Username / account name of DDNS account Password : the Password of DDNS account Domain name : The DDNS name user apply .
Page 46
A.SNMP This section is for development of system integrator who is familiar with SNMP knowledge. In community Authority , user can select “ Read only” or “Read / Write” In “ Trap “ type ,user can select “ v1 trap “ , “ v2c trap “ or “ v2c inform” In MIB file section , user can get MIB information.
Page 47
C.Modbus TCP A. Modbus : We supply 3 models of ModBus control C-1 ModBUS TCP : Just Enable or disable this function - 47 -...
Page 48
C-2 Modbus Gate way model : Need to Enable Modbus , Enable RTU & fill Modbus ID . C-3 Modbus RTU : Need to Enable Modbus , Enable RTU & fill Modbus ID . D.BACnet TCP In this section is for development of system integrator who is familiar with Telnet to enable / disable the function and to setup it`s port .
CNT ( MQTT ) A. IP Service & CNT Setting : The IP SERVICE allow 9820 MT to be accessed easily on the internet by our IP Power Center or IP EDIT. With this feature anyone can find its device with no problems.
Page 50
This allows the device to be accessed easily on the Internet, user no longer have to Port Forwarding , user device to be able to use it. Only some devices are CNT compatible. Please refer page #14 for the function of IP Server B.
4.5 System Setting : 4.5.1 Management In this section there are 5 settings: Administrator setting, Langrage Settings , NTP settings , Import Configuration files and System Reset . Administrator setting In this section allows user to change password for 3 different authorization level . The account name and password can be changed , but each Authorities only support one Account name &...
Page 52
1. Administrator (Admin ) : The Administrator has the authority to create other users, remove users, and control the device. 9820 MT will ask to log in again if change the Default Setting here. 2. Operator : The operator can only control the setting of “ IO Control “ section but can not see other page of 9820 MT .
Page 53
Import configuration file To setup multiple with same setting , user can import the settings of other 9820 MT from a “ DAT “ file which is exported form another 9820 MT . By import this file to other 9820 MT device and shorten the setup time .
Export configuration file : Export the settings into DAT file for import to other 9820 MT Factory Reset : set back to factory default . Reboot : 9820 MT device power reboot 4.5.2 System Information User can get the system information here . 4.5.3 System Log In this section , user can get the 9820 MT system operation information and send the information to assign Server IP address ( not support name ) .
4.5.4 Firmware Please only use the file supply from Aviosys distributor or Aviosys . There are two sections : Bootloader & Firmware The firmware update function only support in LAN connection . Before update , please DO READ THE HI-LITE MESSAGE BLOW : It takes about 1 minute to upload upgrade flash and be patient please.
5.Other ways to control Besides webpahe control ,there are several ways to control the outlets : by HTTPS/CGI command or by Telnet . 9820 MT also support SNMP ( MIB) , Mudbus /TCP and BACnet /TCP . Please check page #41 to check and enable the function . 5.1 CGI HTTP Commands CGI Commands allow you to easily integrate the 9820 MT with other systems and programs.
Page 57
2.4 To get Current : getcurrent http://192.168.1.18/set.cmd?cmd=getcurrent System return: CGI Command : Data follows c61=0.000000, c62=0.000000, c63=0.000000, c64=0.000000, c65=0.000000, c66=0.000000, c67=0.000000, c68=0.000000, temp=22.700001 C61 to C68 means 8 currents ,temp is temperature (as Celsius ) 2.5 To get temperature (Celsius): gettemp http://192.168.1.18/set.cmd?cmd=gettemp System return:...
5.2 Telnet Control Please enable the telnet function in “Application “ → “ Communication “ Or Check page #41 to check and enable the function . - 58 -...
6.FAQ : Q1: Why can`t I see the 9820 MT`s IP address in IPEDIT.exe ? Ans.: Please check the PC you use is under same LAN/ network / segment as 9820 MT . Please turn off some Anti-Virus / online chatting software . If there are morn than 1 network card , include dynamic network card , please disable one and make sure the one you selected is under the same segment with IP9820 MT.
Page 60
Q4: How can I reset to default: Ans : Keep pressing the button of “RESET for 10 seconds at least To reset to original manufacture settings : press the reset button with a sharpen pin for 10 seconds then RELEASE. There will be 3 beeps sound which means reset start and 9820 MT will be rebooted itself -there is one beep after reboot ) and most information go back to default setting ( LAN IP ).
Need help?
Do you have a question about the 9820 MT Series and is the answer not in the manual?
Questions and answers