Maximum altitude............................. 2,000 m
Pollution Degree (IEC 60664) .......... 2

Shock and Vibration

To meet these specifications, you must panel mount the system
and, for the NI 9472 with screw terminal and NI 9474, affix
ferrules to the ends of the terminal wires.
Operating vibration,
random (IEC 60068-2-64) ................ 5 g
Operating shock
(IEC 60068-2-27).............................. 30 g, 11 ms half sine,
Operating vibration,
sinusoidal (IEC 60068-2-6) .............. 5 g, 10 to 500 Hz

Electromagnetic Compatibility

Emissions.......................................... EN 55011 Class A at 10 m
© National Instruments Corp.
, 10 to 500 Hz
rms
50 g, 3 ms half sine,
18 shocks at 6 orientations
FCC Part 15A above 1 GHz
25
NI 9472/9474 Operating Instructions