Setting Into Operation; Specifications - Monacor IMG STAGELINE VU-800/SW Instruction Manual

Vu-meter
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 7

5 Setting into Operation

Prior to connecting any units or to changing existing connec-
tions, switch off the VU meter .
1) Connect the stereo input AUDIO IN (6) to a line level output
of the unit whose level is to be indicated, e . g . effect unit,
mixer .
2) A subsequent unit (e . g . amplifier, second mixer) can be
connected to the stereo feed-through output AUDIO
OUT  (7) . Connect the output AUDIO OUT to a line level
input of the unit .
3) Connect the power supply unit provided to the jack
"12 V ⎓ " (5) and then to a mains socket (230 V/ 50 Hz) .
4) Prior to the first operation, a basic adjustment of the
VU meter must be made (
5) Switch on the VU meter with the POWER switch (4) . Select
the display mode of the LEDs (3) via the switch (2):
Position BAR = bargraph display
Example: If a level of −12 dB is measured for a channel,
all LEDs "−45 dB" to "−12 dB" will light up .
Position DOT = dot display
Example: If a level of −12 dB is measured for a channel,
only the two LEDs "−12 dB" will light up .
6) Feed the audio signals to the VU meter and read the signal
chapter 4) .
levels on the LED display . An optimum adjustment of the
signal source has been obtained when the "0 dB" LEDs light
up during music peaks . In case of overload (ranges exceed-
ing "0 dB" light up), reduce the level of the signal source .
7) For switching off, press the POWER switch . If the VU meter
is not used for a longer period, disconnect the power sup-
ply unit from the mains socket as the power supply unit will
have a low current consumption even when the VU meter
has been switched off .

6 Specifications

Version: 3-coulour LED display of 40 LEDs per channel
Display range: steps of 3 dB from −45 dB dB to +12 dB
Input sensitivity: approx 350 mV – 7 V
Power supply: via power supply unit provided, connected to
230 V/ 50 Hz
Ambient temperature: 0 – 40 °C
Dimensions (W × H × D): 482 × 44 5 × 52 mm, 1 rack space
Weight: 795 g
Subject to technical modification .