ThermoWorks Thermapen Blue Operating Instructions

ThermoWorks Thermapen Blue Operating Instructions

Advertisement

Quick Links

SPECIFICATIONS
Range
–58 to 572°F (–49.9 to 299.9°C)
Accuracy
±0.7°F (±0.4°C) from –58 to 392°F (–49.9 to 199.9°C)
otherwise ±1.8°F (±1.0°C)
Response
2-3 sec. (reads to within 1°F of final temperature of an ice bath in 3 sec.)
Resolution
0.1° via remote device
Battery
1 x AAA / 1000 hours
Sensor
High-performance Type K thermocouple
Connection
Requires Bluetooth 4.1 or above
Probe
0.125 dia. x 4.3 L inches ( 3.3 dia. x 109 L mm)
with reduced tip to 0.06 dia. inches (1.5 dia. mm)
Water Resistance
IP67
Environmental Range
–4 to 122°F (–20 to 50°C)
Dimensions
1.97 H x 6.2 W x 0.75 D inches (50 H x 157 W x 19 D mm)
Weight
0.26 lbs (120g)
Calibration
NIST-traceable certificate included
RADIO CERTIFICATIONS
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this
device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired
operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est
autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain
approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should
be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain
maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique
à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente
(p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante.
Made in the UK
741 E. Utah Valley Dr., American Fork, UT 84003
Ph: 801-756-7705 Fax: 801-756-8948
P-17-010-02-g
thermoworks.com
Ref: 547-600 22.01.20
Thermapen
Operating Instructions
Blue
®

Advertisement

loading

Summary of Contents for ThermoWorks Thermapen Blue

  • Page 1 à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire à l’établissement d’une communication satisfaisante. Made in the UK Operating Instructions 741 E. Utah Valley Dr., American Fork, UT 84003 Ph: 801-756-7705 Fax: 801-756-8948 P-17-010-02-g thermoworks.com Ref: 547-600 22.01.20...
  • Page 2 Red - battery low No lights - battery flat • If the amber light starts flashing rapidly during startup, Thermapen Blue us updating firmware. Please leave the probe open and wait for the rapidly flashing lights to stop before The battery status can also be viewed using HACCP LE on a phone/tablet.