Alcatel 1660SM Installation Handbook page 41

Stm-64 multiservice metro node
Hide thumbs Also See for 1660SM:
Table of Contents

Advertisement

P16S1-4E
1)
This board can be inserted in slots from 24 to 39. It is possible to insert a maximum of 16 boards.
Inserting the A12OS1E board (for optical access) or the A16ES1E board (for electrical access) into the
"Access Zone" subrack can increase the number of accesses through this board.
A12OS1E
1)
This board can be inserted in slots from 2 to 8 and from 13 to 20. It is possible to insert a maximum of 8
boards.
The P16S1-4E board drives this board.
A16ES1E
1)
This board can be inserted in slots from 2 to 9 and from 13 to 20. It is possible to insert a maximum of
16 boards.
The P16S1-4E board drives this board.
COWLA2
1)
This board can be inserted in slots from 24 to 39. It is possible to insert a maximum of 16 boards.
COADM1
1)
This board can be inserted in slots from 1 to 8 and from 13 to 20. It is possible to insert a maximum of 8
boards.
4xANYC
1)
This board can be inserted into slots 25-26, 28-29, 32-33, 34-35 and 37-38. It is possible to insert a
maximum of 6 boards.
COMDX
1)
This board can be inserted in slots from 1 to 8 and from 13 to 20. It is possible to insert a maximum of 8
boards.
ISA-ES16
1)
This board can be inserted in slots from 24 to 39. It is possible to insert a maximum of 8 boards.
The Ethernet ports are accessed through the GETH-AG or ETH-ATX boards on the access side.
ES1-8FX
1)
This board can be inserted in slots from 24 to 39. It is possible to insert a maximum of 8 boards.
It is equipped with SFP modules.
ED
03
8DG 15436 BAAA
41/140