Cabinet And Duct Dimensions; Electrical And Performance Data - York AFFINITY PT9 Technical Manual

York international gas-fired condensing / high efficiency downflow/horizontal two stage furnaces technical guide
Table of Contents

Advertisement

246782-YTG-B-0407
22-3/4
7/8
7/8
13-7/8
HORIZONTAL CONDENSATE
DRAIN OPENING 2"
JUNCTION BOX
HOLE 7/8"
GAS PIPE ENTRY 1-1/2"
CONDENSATE DRAIN
HOLE 7/8"
SIDE PIPING HOLE 3-3/8"
22-1/4
25-3/8
26-1/2
27-1/8
30-1/8
LEFT SIDE

CABINET AND DUCT DIMENSIONS

Models
PT9B12N060DH11
PT9B12N080DH11
PT9C16N080DH11
PT9C20N100DH11
PT9D20N120DH11

ELECTRICAL AND PERFORMANCE DATA

Input
(High/Low)
Models
MBH
PT9B12N060DH11
60 / 39
PT9B12N080DH11
80 / 52
PT9C16N080DH11
80 / 52
PT9C20N100DH11
100 / 65
PT9D20N120DH11
120 / 78
Input
(High/Low)
Models
MBH
PT9B12N060DH11
60 / 39
PT9B12N080DH11
80 / 52
PT9C16N080DH11
80 / 52
PT9C20N100DH11
100 / 65
PT9D20N120DH11
120 / 78
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
* Wire size and overcurrent protection must comply with the National Electric Code.
NOTES:
1. For altitudes above 2000 ft. reduce capacity 4% for each 1000 ft. above sea level.
2. Wire size based on copper conductors, 60°C, 3% voltage drop.
3. Continuous return air temperature must not be below 55°F.
4. All filters must be high velocity cleanable type.
2
T-STAT WIRING 7/8" K.O.
HORIZONTAL CONDENSATE
DRAIN OPENING 1-3/4"
29
22-3/4
21-5/8
18-1/2
11-3/4
7-1/2
2-1/4
23-11/16
19-1/4
1-1/4
C
BOTTOM IMAGE
SUPPLY END
CABINET
CFM
SIZE
1200
B
1200
B
1600
C
2000
C
2000
D
Output
Nominal
(High/Low)
Airflow
MBH
CFM
56 / 36
1200
75 / 49
1200
75 / 49
1600
93 / 61
2000
112 / 74
2000
Max. Outlet
Blower
Air Temp.
°F
HP
165
1/2
165
1/2
165
3/4
165
1
165
1
A
40
29
22-3/4
21-1/4
FRONT
23-5/8
1-1/4
D
E
20
2-1/4
23-1/4
TOP IMAGE
RETURN END
CABINET DIMENSION
A (IN.)
B (IN.)
17-1/2
16-1/4
17-1/2
16-1/4
21
19-3/4
21
19-3/4
24-1/2
23-1/4
Cabinet
Total Unit
Width
In.
Amps
17-1/2
17-1/2
21
21
24-1/2
Blower
Max.
Size
Over-current
Protect
Amps
In.
7.0
11 x 8
7.0
11 x 8
10.2
11 x 10
12.7
11 x 11
12.7
11 x 11
T-STAT WIRING 7/8" K.O.
HORIZONTAL CONDENSATE
DRAIN OPENING 1-3/4"
HORIZONTAL
CONDENSATE
DRAIN OPENING 1-3/4"
JUNCTION BOX
HOLE 7/8"
GAS PIPE
18-1/2
ENTRY 1-1/2"
9-1/8
CONDENSATE DRAIN
8-1/2
HOLE 7/8"
RIGHT SIDE
5/8
5/8
B
C (IN.)
D (IN.)
15
1-3/4
15
1-3/4
18-1/2
2-1/8
18-1/2
2-1/8
22
2-1/2
AFUE
%
9
92
9
92
12
92
14
92
14
92
Min. Wire Size
(awg) @ 75 ft.
One Way
20
14
20
14
20
14
20
12
20
12
Unitary Products Group
E (IN.)
2-3/8
2-3/8
2-3/4
2-3/4
3
Air Temp.
Rise
°F
35 - 65
35 - 65
35 - 65
35 - 65
35 - 65
Operating
Weight
Lbs.
136
143
159
164
182