Cabinet And Duct Dimensions; Electrical And Performance Data - York GY9F*DH series Technical Manual

Gas-fired condensing / high efficiency downflow/horizontal furnace
Table of Contents

Advertisement

339033-YTG-A-0607
T-STAT WIRING 7/8" K.O.
HORIZONTAL CONDENSATE
DRAIN OPENING 1-3/4"
HORIZONTAL CONDENSATE
DRAIN OPENING 2"
JUNCTION BOX
HOLE 7/8"
GAS PIPE ENTRY 1-1/2"
CONDENSATE DRAIN
HOLE 7/8"
SIDE PIPING HOLE 3-3/8"
28-1/2
LEFT SIDE
1-1/4

CABINET AND DUCT DIMENSIONS

Models
GY9F064C16DH11
GY9F080C16DH11

ELECTRICAL AND PERFORMANCE DATA

Models
GY9F064C16DH11
GY9F080C16DH11
Models
GY9F064C16DH11
GY9F080C16DH11
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
Wire size and overcurrent protection must comply with the National Electric Code.
NOTES:
1. For altitudes above 2000 ft. reduce capacity 4% for each 1000 ft. above sea level.
2. Wire size based on copper conductors, 60°C, 3% voltage drop.
3. Continuous return air temperature must not be below 55°F.
4. All filters must be high velocity cleanable type.
2
1-1/4
19-1/4
C
BOTTOM IMAGE
SUPPLY END
Cabinet
CFM
Size
1600
C
1600
C
Input/
Output
Cabinet
MBH
MBH
64/C
61
80/C
76
Input/
Max. Outlet
Cabinet
Air Temp.
MBH
°F
HP
64/C
165
3/4
80/C
165
3/4
A
40
FRONT
D
2-1/4
RETURN END
A (in.)
B (in.)
21
19-3/4
21
19-3/4
Nominal
Cabinet
Airflow
Width
CFM
In.
1600
21
1600
21
Blower
Blower
Size
Amps
In.
10.2
11 x 10
10.2
11 x 10
T-STAT WIRING 7/8" K.O.
HORIZONTAL CONDENSATE
DRAIN OPENING 1-3/4"
HORIZONTAL
CONDENSATE
DRAIN OPENING 1-3/4"
JUNCTION BOX
HOLE 7/8"
GAS PIPE
ENTRY 1-1/2"
CONDENSATE DRAIN
HOLE 7/8"
RIGHT SIDE
23-5/8
5/8
5/8
B
20
23-1/4
TOP IMAGE
Cabinet Dimension
C (in.)
18-1/2
18-1/2
Total Unit
AFUE
Amps
%
12
95
12
95
Max.
Min. Wire Size
Over-current
(awg) @ 75 ft.
Protect
One Way
20
14
20
14
Unitary Products Group
D (in.)
2-1/8
2-1/8
Air Temp.
Rise
°F
25 - 55
25 - 55
Operation
Weight
Lbs.
155
170

Advertisement

Table of Contents
loading

Table of Contents