Electrical Data Dr120 W/O Pwrd Convenience Outlet; Electrical Data Dr120 With Pwrd Convenience Outlet; Ytg-C - York PREDATOR MagnaDRY DR090 Technical Manual

Single package air conditioners and single package gas/electric units
Hide thumbs Also See for PREDATOR MagnaDRY DR090:
Table of Contents

Advertisement

246721-YTG-C-0606

TABLE 13: ELECTRICAL DATA DR120 W/O PWRD CONVENIENCE OUTLET
OD Fan
Compressors
Motors
Voltage
RLA
LRA
FLA
ea.
ea.
ea.
208
16.0
137.0
3.5
230
16.0
137.0
3.5
460
8.3
69.0
1.6
575
6.4
58.0
1.3
*
Maximum HACR breaker of the same AMP size is applicable.
TABLE 14: ELECTRICAL DATA DR120 WITH PWRD CONVENIENCE OUTLET
OD Fan
Compressors
Motors
Voltage
RLA
LRA
FLA
ea.
ea.
ea.
208
16.0
137.0
3.5
230
16.0
137.0
3.5
460
8.3
69.0
1.6
575
6.4
58.0
1.3
*
Maximum HACR breaker of the same AMP size is applicable.
Unitary Products Group
Pwr
Supply Blower
Pwr Exh
Conv
Motor FLA
Motor
Outlet
2
3
FLA
FLA
HP
HP
8.2
10.9
5.5
0.0
8.2
10.9
5.5
0.0
4.1
5.3
2.2
0.0
3.6
4.1
1.8
0.0
Pwr
Supply Blower
Pwr Exh
Conv
Motor FLA
Motor
Outlet
2
3
FLA
FLA
HP
HP
8.2
10.9
5.5
10.0
8.2
10.9
5.5
10.0
4.1
5.3
2.2
5.0
3.6
4.1
1.8
4.0
Electric Heater
Actual
Heater
Model No.
KW
Amps
None
--
--
2TP04521825
13.5
37.5
2TP04522425
18.0
50.0
2TP04523625
25.5
70.8
2TP04525425
40.6
112.7
151.1
None
--
--
2TP04521825
18.0
43.3
2TP04522425
24.0
57.7
2TP04523625
34.0
81.8
112.5
2TP04525425
54.0
129.9
140.2
None
--
--
2TP04521846
18
22.6
2TP04522446
24
30.1
2TP04523646
34
42.7
2TP04525446
54
67.8
None
--
--
2TP04521858
18
18.1
2TP04522458
24
24.1
2TP04523658
34
34.1
2TP04525458
54
54.2
Electric Heater
Actual
Heater
Model No.
KW
Amps
None
--
--
2TP04521825
13.5
37.5
2TP04522425
18.0
50.0
2TP04523625
25.5
70.8
111.2
2TP04525425
40.6
112.7
163.6
None
--
--
2TP04521825
18.0
43.3
2TP04522425
24.0
57.7
2TP04523625
34.0
81.8
125.0
2TP04525425
54.0
129.9
152.7
None
--
--
2TP04521846
18
22.6
2TP04522446
24
30.1
2TP04523646
34
42.7
2TP04525446
54
67.8
None
--
--
2TP04521858
18
18.1
2TP04522458
24
24.1
2TP04523658
34
34.1
2TP04525458
54
54.2
Min. Circuit
MCA w/Power
Max Fuse* Size
Ampacity
Exhaust (Amps)
(Amps)
(Amps)
2
3
2
3
2
HP
HP
HP
HP
HP
51.2
53.9
56.7
59.4
60
57.1
60.5
64.0
67.3
60
72.7
76.1
79.6
83.0
80
98.7
102.1
105.6
109.0
100
154.5
158.0
161.4
175
51.2
53.9
56.7
59.4
60
64.4
67.8
71.3
74.6
70
82.4
85.8
89.3
92.7
90
115.9
119.4
122.7
125
143.5
147.0
150.4
150
26
27.2
28.2
29.4
30
32.2
33.7
34.9
36.4
35
41.2
42.7
44
45.5
45
56.2
57.7
59
60.5
60
70.1
71.6
72.8
74.3
80
20.6
21.1
22.4
22.9
25
26.2
26.8
28.4
29
30
33.4
34
35.6
36.2
35
45.4
46
47.6
48.3
50
56.5
57.1
58.7
59.3
70
Min. Circuit
MCA w/Power
Max Fuse* Size
Ampacity
Exhaust (Amps)
(Amps)
(Amps)
2
3
2
3
2
HP
HP
HP
HP
HP
61.2
63.9
66.7
69.4
70
69.6
73.0
76.5
79.8
70
85.2
88.6
92.1
95.5
90
114.6
118.1
121.5
125
167.0
170.5
173.9
175
61.2
63.9
66.7
69.4
70
76.9
80.3
83.8
87.1
80
94.9
98.3
101.8
105.2
100
128.4
131.9
135.2
125
156.0
159.5
162.9
175
31
32.2
33.2
34.4
35
38.4
39.9
41.2
42.7
40
47.5
49
50.2
51.7
50
62.5
64
65.2
66.7
70
76.3
77.8
79.1
80.6
90
24.6
25.1
26.4
26.9
30
31.2
31.8
33.4
34
35
38.4
39
40.6
41.2
40
50.4
51
52.6
53.3
60
61.5
62.1
63.7
64.3
70
Max Fuse Size
w/Power
Exhaust (Amps)
3
2
3
HP
HP
HP
60
70
70
70
70
70
80
80
90
110
110
110
175
175
175
60
70
70
70
80
80
90
90
100
125
125
125
175
175
175
35
35
35
35
35
40
45
45
50
60
60
70
80
80
80
25
25
25
30
30
30
35
40
40
50
50
50
70
70
70
Max Fuse Size
w/Power
Exhaust (Amps)
3
2
3
HP
HP
HP
70
80
80
80
80
80
90
100
100
125
125
125
175
175
175
70
80
80
90
90
90
100
110
110
150
150
150
175
175
175
40
40
40
40
45
45
50
60
60
70
70
70
90
90
90
30
30
30
35
35
35
40
45
45
60
60
60
70
70
70
27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Predator magnadry dr120Predator magnadry dr150

Table of Contents