TABLE 35: 10 TON STANDARD EFFICIENCY SUPERHEAT CHARGING
Outdoor
Temp (°F)
55
65
19.6
70
14.4
75
9.3
80
-
85
-
90
-
95
-
100
-
105
-
110
-
115
-
TABLE 36: 12.5 TON STANDARD EFFICIENCY SUPERHEAT CHARGING
Outdoor
Temp (°F)
55
65
33.6
70
29.6
75
25.6
80
21.6
85
17.6
90
11.6
95
5.6
100
-
105
-
110
-
115
-
38
Superheat at Compressor Suction (°F)
57
59
61
20.8
22.0
23.2
16.0
17.5
19.0
11.1
12.9
14.7
6.3
8.4
10.5
-
-
6.3
-
-
5.6
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Superheat at Compressor Suction (°F)
57
59
61
34.2
34.7
35.3
30.4
31.1
31.9
26.6
27.5
28.5
22.8
24.0
25.1
19.0
20.4
21.7
13.4
15.2
16.9
7.8
10.0
12.1
6.1
7.8
9.4
-
5.5
6.7
-
-
-
-
-
-
Airflow = 4000 CFM
Indoor WB Temp (°F)
63
65
67
24.4
25.6
26.9
20.5
22.0
23.5
16.6
18.4
20.2
12.6
14.8
16.9
8.7
11.1
13.6
7.8
9.9
12.0
6.8
8.7
10.5
5.3
6.7
8.1
-
-
5.7
-
-
-
-
-
-
Airflow = 5000 CFM
Indoor WB Temp (°F)
63
65
67
35.9
36.4
37.0
32.7
33.4
34.2
29.5
30.5
31.4
26.3
27.5
28.6
23.1
24.5
25.9
18.7
20.5
22.3
14.3
16.5
18.7
11.1
12.8
14.5
7.9
9.1
10.3
-
5.4
6.1
-
-
-
035-17311-002-A-0803
69
71
73
28.4
29.9
31.4
25.4
27.3
29.2
22.4
24.7
26.9
19.5
22.0
24.6
16.5
19.4
22.4
15.0
17.9
20.8
13.4
16.3
19.3
10.8
13.5
16.2
8.1
10.6
13.1
5.5
7.7
10.0
-
-
6.9
69
71
73
37.3
37.5
37.8
34.7
35.3
35.8
32.2
33.0
33.8
29.7
30.8
31.8
27.2
28.5
29.9
24.3
26.3
28.3
21.3
24.0
26.7
17.5
20.6
23.7
13.8
17.2
20.7
10.0
13.8
17.6
6.2
10.4
14.6
Unitary Products Group
75
32.9
31.0
29.1
27.2
25.3
23.7
22.2
18.9
15.5
12.2
8.9
75
38.0
36.3
34.6
32.9
31.2
30.3
29.4
26.7
24.1
21.5
18.8