Page 1
EasyIO FD-20i User Reference v1.2 EasyIO FD-20i Series User Reference...
Page 2
EasyIO FD-20i User Reference v1.2 Document Change Log June 2019 Document created. June 2019 Update power supply details March 2020 Updated the temp table selection.
Page 3
While every effort has been made to assure the accuracy of this document, EasyIO Holdings Pte Ltd is not responsible for damages of any kind, including without limitation consequential damages, arising from the application of the information contained herein.
Page 4
EasyIO FD-20i User Reference v1.2 Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Introduction The EasyIO FD Series is aimed at affordable IO module range. EasyIO FD-20i Series controller comes with built in bootloader program. Built in bootloader program will enable user to upgrade firmware without sending back to factory. EasyIO FD20 do not have an Ethernet port.
Hardware Configurations Power supply Connection Both AC and DC can be used for EasyIO FD-20i controller. Refer to electrical specification for the working range. In order to avoid damage on the controller input/output devices and RS485 connection, use individual power supply for each controller. If a single power supply is used, make sure controller power supplies are connected with the same polarity.
RS485 Connection RS 485 Serial port settings. Every EasyIO FC controller comes with 1 physical RS -485 ports respectively. However EasyIO provide 2 sets of RS-485 terminals for easy wiring terminations. Below is a table showing the default details for serial port.
Page 9
For serial addressing it uses binary bit. The Least Significant Bit (LSB) in DIP 8. The Most Significant Bit (MSB) is DIP 2. The white the spot/white square represent the DIP switch toggle button. EasyIO FC-20 enlarged DIP switch Setting DIP switch Functions...
EasyIO FD-20i User Reference v1.2 Universal Input Connection EasyIO FD-20i has ten (10) non-isolated universal inputs. The universal input supports either resistance or digital voltage free contacts. Resistance – The working range of resistance is 400 Ohm – 300 KOhms. If the input is configured as Thermistor type, the system provides 10 customizable temperature lookup tables for resistance to temperature translation.
Page 11
EasyIO FD-20i User Reference v1.2 Physical Input Terminal Digital Imput Block Channel DI 1 DI 1 DI 2 DI 2 DI 3 DI 3 DI 4 DI 4 DI 5 DI 5 DI 6 DI 6 DI 7 DI 7...
EasyIO FD-20i User Reference v1.2 Buttons and Indications The controller will perform a hardware reset when the Reset Button is toggle. The Service button is used to activate the built-in bootloader program for software upgrade. Each digital output has a correspondence LED to indicate its current state.