Download Print this page

Absolute Process Instruments API 4058 G Series Quick Manual

Strain gauge/bridge/load cell/pressure transducer to dc transmitters, field rangeable

Advertisement

Quick Links

Strain Gauge/Bridge/Load Cell/Pressure Transducer to DC Transmitters, Field Rangeable
One to Four 350 Ω Sensors, 0-5 mV to 0-1200 mV, 4-10 VDC Excitation
Input:
Output:
0-1 V to ±10 V or 0-1 mA to 4-20 mA, Non-Isolated
 Drive up to Four 350 Ω Bridges
 Adjustable Excitation Power Supply
 One Minute Setup for Hundreds of I/O Ranges
 Easy-to-use External Switches for Setup
 Hot-Swappable Plug-In Design
®
 Input and Output LoopTracker
LEDs
 Adjustable Output Test
 Internal Calibration Resistor Option
Applications
 Load Cell Weighing Systems and Scales
 Strain Gauge Pressure Sensors and Transducers
 Tanks, Scales, Extruder Melt Pressure, Crane Loads
Input Range
Minimum range:
0 to 5 mV
Maximum range:
0 to 1200 mV
Minimum sensitivity:
0.5 mV/V
Maximum sensitivity: 120 mV/V
Millivolt output range is determined by the sensitivity of the
sensor (mV/V) and the excitation voltage applied.
mV/V sensitivity X excitation voltage = total mV range
Input Impedance
1 MΩ typical
Calibration Resistor Option
M01 option:
Toggle switch for internal shunt resistor
Excitation Voltage
Maximum output: 10 VDC maximum at 115 mA
Up to four 350 Ω bridges at 10 VDC
Drive capability:
Adjustability: Switch-selectable, 0-10 VDC in 1 V increments
Fine adjustment: ±2.5% via multiturn potentiometer
Stability:
±0.01% per °C
LoopTracker
Variable brightness LEDs for input/output loop level and status
Output Ranges
Minimum
Maximum
Voltage:
0-1 VDC
0-10 VDC
Bipolar Voltage:
±1 VDC
±10 VDC
Current:
0-2 mADC
0-25 mADC
20 V compliance, 1000 Ω at 20 mA
Output Linearity, Ripple & Noise
Better than ±0.1% of span, <10 mV
RMS
Output Zero and Span
Multi-turn potentiometers to compensate for load and lead
variations, ±15% of span adjustment range typical
Zero Offset
±100% of span in 15% increments
Functional Test Button
Sets output to test level when pressed
Adjustable 0-100% of span
Not available with M01 option
Response Time
150 milliseconds typical (6.6 Hz)
DF option: 75 millisecond response time typical (13.3 Hz)
Contact factory for faster response times
Common Mode Rejection
100 dB minimum
Ambient Temperature Range and Stability
–10°C to +60°C operating ambient
Better than ±0.02% of span per °C stability
Housing and Sockets
IP 40, plugs into API 011 or API 011 FS socket
Socket mounts to 35 mm DIN rail or can be surface mounted
Power
Standard:
115 VAC ±10%, 50/60 Hz, 2.5 W max.
A230 option: 230 VAC ±10%, 50/60 Hz, 2.5 W max.
P option:
60-265 VAC, 50/60 Hz or 85-300 VDC,
2.5 W typical
D option:
9-30 VDC, 2.5 W typical
BSOLUTE
Output Test
Button
Variable
Brightness
Input LED
Variable
Brightness
Output LED
Output
Calibration
Output Test
Setting
Free Factory
Free Factory
I/O Setup!
I/O Setup! p
Description
The API 4058 G accepts a strain gauge, bridge, load cell,
or a summed input from up to four sensors, and provides
a proportional, non-isolated DC voltage or current output. It
includes filtering and processing to allow effective use of low-
level transducers in the noisy environments found in industrial
applications.
The built-in 115 mA bridge excitation power supply generates a
stable source of excitation voltage to drive from one to four 350
Ω (or greater) bridge type sensors such as load cells, pressure
ripple and noise
transducers and strain gauges The API 4058 G amplifies and
converts the resulting millivolt signal into the selected output.
Input, output, excitation, and zero offset are field configurable,
via external rotary and slide switches. Common ranges are
on the module label. An offset switch is standard for appli-
cations requiring cancellation of sensor offsets or non-zero
deadweights (taring). Zero and span potentiometers allow
calibration of the output.
How to Order
Please specify
Model API 4058 G (operates on 115 VAC)
D for operation on low voltage power
A230 for 230 VAC operation
P for wide ranging power
Options as required
Resistor value if ordering M01 option
Model
API 4058 G
API 4058 G A230
API 4058 G P
API 4058 G D
Options–add to end of model number
M01
Built-in calibration resistor. Specify resistor value.
DF
75 millisecond response time, or consult factory
U
Conformal coating for moisture resistance
ROCESS NSTRUMENTS, Inc.
2.38"
1.75"
1
1
1
1
1
1
Minute
Minute
Setup!
S
S et
S
S
up!
!
!
Input
Field configurable—specify mV/V
and excitation voltage if factory is
Specify range if factory is to set
to set switches, specify calibra-
tion resistor value, if required
1220 American Way Libertyville, IL 60048
Phone:
800-942-0315
API 4058 G
11-Pin Socket
Sold Separately
Hot Swappable
Plug-In Design
Quick Link
api-usa.com/4058
LoopTracker
API exclusive features include two LoopTracker LEDs (green for
input, red for output) that vary in intensity with changes in the
process input and output signals. These provide a quick visual
picture of your process loop at all times and can greatly aid in
saving time during initial startup and/or troubleshooting.
Output Test
An API exclusive feature includes the test button to provide a
fixed output (independent of the input) when held depressed.
The test output level is potentiometer adjustable from 0 to
100% of output span. The output test button greatly aids in
saving time during initial startup and/or troubleshooting.
The output test is not available with the M01 option. A calibra-
tion resistor switch replaces the test button.
Mounting
The API 4058 G plugs into an industry standard 11-pin octal
socket sold separately. Sockets API 011 and finger-safe API
011 FS allow either DIN rail or panel mounting.
Switches can be pre-set to your specifications.
Please provide
Bridge mV/V
Excitation voltage
Output range
Output
Field configurable
60-265 VAC or 85-300 VDC
switches
9-30 VDC or 10-32 VAC
Accessories—order as separate line item
API 011
11-pin socket
API 011 FS 11-pin finger-safe socket
API TK36
DIN rail, 35 mm W x 39" L, aluminum
© 10-11
api-usa.com
Fax: 800-949-7502
2.75"
★ ★ ★ ★ ★ ★
Made
★ ★ ★ ★ ★
★ ★ ★ ★ ★ ★
★ ★ ★ ★ ★
★ ★ ★ ★ ★ ★
★ ★ ★ ★ ★
★ ★ ★ ★ ★ ★
★ ★ ★ ★ ★
in
★ ★ ★ ★ ★ ★
U S A
Power
115 VAC
230 VAC

Advertisement

loading

Summary of Contents for Absolute Process Instruments API 4058 G Series

  • Page 1 Strain Gauge/Bridge/Load Cell/Pressure Transducer to DC Transmitters, Field Rangeable API 4058 G One to Four 350 Ω Sensors, 0-5 mV to 0-1200 mV, 4-10 VDC Excitation Input: Output: 0-1 V to ±10 V or 0-1 mA to 4-20 mA, Non-Isolated ...
  • Page 2 Instructions API 4058 G Installation Precautions 2-10 0-10 ±5 ±10 2-10 0-10 0-16 4-20 0-20 Output WARNING! All wiring must be performed by a qualified electri- cian or instrumentation engineer. Consult factory for assistance. Switches BCDE BCDE BCDE BCDE BCDE BCDE BCDE BCDE BCDE BCDE BCDE BCDE BCDE BCDE BCDE BCDE The module is designed to be mounted in a housing or panel.

This manual is also suitable for:

Api 4058 gApi 4058 g a230Api 4058 g pApi 4058 g d