1. Water Level
• Check water level in tank periodically during operation. With vacuum off, the water level should be at the Fill Line
• If water level drops below the Fill Line, turn the system off and refill the tank
2. When to Change the Water
• When the water in the tank appears dirty and discolored, empty and refill the vacuum
• If the vacuum is used for the collection of combustible metals or dust, the water should be emptied at the end of each shift
• At a minimum, the water should be emptied once per day
• When not in use, the vacuum should be stored with the tank empty and the gate valve open to allow air circulation
3. Changing the Water Using a Filter Sock
• Turn the vacuum power switch to the OFF position and disconnect from power
• Slide a filter sock over the drain spout in the lower compartment of the tank
• Use the spring clamp to lock the filter onto the spout
• Position the tank over a floor drain
• Grasp the handle of the gate valve and pull it away from the unit to open. Water and debris will flow into the filter sock
• When the tank is empty, connect a garden hose to the water inlet and open the ball valve to start water flowing
• Let water run through the system for approximately 60 seconds. The spray heads will thoroughly rinse the tank interior
• If the system is going to be stored, turn the water off and leave the gate valve open to ensure the tank is fully drained
• If the system is going back into use, close the gate valve and let the water continue to flow until the water level reaches the Fill Line
• Remove the filter sock and discard
4. Changing the Water Using a Drain Hose
• Turn the vacuum power switch to the OFF position and disconnect from power
• Connect the drain hose to the drain spout
• Position the tank near a floor drain. Place the end of the hose over the floor drain.
• Grasp the handle of the gate valve and pull it away from the unit to open.
• When the tank is empty, connect a garden hose to the water inlet and open the ball valve to start water flowing
• Let water run through the system for approximately 60 seconds. The spray heads will thoroughly rinse the tank interior
• If the system is going to be stored, turn the water off and leave the gate valve open to ensure the tank is fully drained
• If the system is going back into use, close the gate valve and let the water continue to flow until the water level reaches the Fill Line
• Remove the drain hose or coil it and store in the lower portion of the tank
5.Coalescing Filter Cleaning and Maintenance
• It is recommended to clean the coalescing filter after every 30 uses of the vacuum
• It is recommended to replace the coalescing filter every two years
• Turn the vacuum power switch to the OFF position and disconnect from power
• Unlatch the power head and remove from the tank
• Remove the tank gasket by peeling it up and away from the tank rim
• Grasp the coalescing filter by the steel frame, and pull it up and out of the tank
• Rinse the filter thoroughly with water to remove any debris