Compressed Air Fittings - Clayton Barracuda Electric Safety, Operation & Maintenance

Immersion separator 120v / 220v with pneumatic tool sync
Table of Contents

Advertisement

WARNING
1. Power Head Vents
• NEVER BLOCK THE POWER HEAD VENTS
• NEVER WRAP THE POWER CORD AROUND THE POWER HEAD VENTS
2. Remove and identify the Vacuum,
Included in the Box.
3. If Needed Install the Power Head
• Install the HEPA filter on the power head by threading the filter onto the threaded adapter until snug
• Place the power head on top of the vacuum tank
• Secure the head in place with the tank draw latches
4. Activate the HEPA Filter Timer
• The HEPA Timer Card is attached to the Power Head
• Follow the directions on Timer Card to activate
5. Fill the Tank with Water
• Ensure that the gate valve in the lower compartment is closed by pushing the valve plunger handle in
• Connect a garden hose to the water inlet directly above the vacuum inlet
• Turn the water on
• Open the ball valve on the water inlet to begin filling
• Close the ball valve and disconnect the hose when the water level reaches the Fill Line on the Barracuda sight window
6. Water Level Sensor
• Ensure That the Water Level Sensor Cable is Connected from the Tank to the Power Head
7. Power Switch
• Set the Power Switch to the Off Position
The vacuum has the following Compressed Air Requirements to function properly.
• Compressed air must be clean, dry, and oil free to prevent blockage of the pneumatic system
• Compressed air line and fittings must have a minimum diameter of 1/4in (7mm)
Compressed Air Plug (air in)
• The Vacuum is supplied with a 1/4in (7mm) industrial interchange compressed air plug for connection to your compressed air supply
The Compressed Air Plug may be changed to another nominal 1/4in (7mm) style if required.
• Hold the brass bulkhead fitting with a 1in (26mm) open end wrench
• Remove the compressed air plug with either a 9/16in (15mm)deep socket or 9/16in (15mm)open end wrench
• Install a new compressed air plug
Compressed Air Coupler (air out)
• The Vacuum is supplied with two 1/4in (7mm) brass high flow compatible industrial interchange compressed air couplers
• This coupler provides convenient pass through compressed air for an air tool connected to the vacuum
The Compressed Air Coupler may be changed to another nominal 1/4in (7mm) style if required.
• Hold the brass bulkhead fitting with a 1in (26mm) open end wrench
• Remove the compressed air coupler with a 3/4in (19mm) open end wrench
• Install a new compressed air coupler
Repair or Warranty Contact
Page 6
GETTING STARTED
onsumables, and Accessories
C

COMPRESSED AIR FITTINGS

Clayton Associates, Inc.
1650 Oak Street
Vents
Lakewood, New Jersey 08701
www.DustlessMadeSimple.com
P.+1-732-363-2100 F.+1-732-364-6084
Sales@JClayton.com